Allen-Bradley 1756-L65 ControlLogix Processor – Logix5565 CPU with 32 MB User Memory

Status: In Stock

he Allen-Bradley 1756-L65 is a ControlLogix 5560 standard controller (Logix5565 processor) manufactured by Rockwell Automation for the 1756 ControlLogix chassis family. Sitting at the top of the 5560 memory tier, it delivers 32 MB of user memory for data and logic and 478 KB of dedicated I/O memory, driving up to 128,000 digital I/O points and 4,000 analog I/O points across one of the most widely deployed modular control platforms in industrial automationsantaclarasystems.com+1.

Communicating natively over EtherNet/IP, ControlNet, DeviceNet, Remote I/O, Data Highway Plus, SynchLink, and third-party process networks — with serial protocols including DF1, ASCII, Modbus via logic, and DH-485 on the built-in RS-232 port — the 1756-L65 is the central brain for large discrete assembly lines, batch processes, motion systems, and redundant SCADA architectures where Rockwell’s Logix platform is the plant standard

Allen-Bradley 1756-L65 ControlLogix Processor – Logix5565 CPU with 32 MB User Memory插图

 

Application Scenarios

Consider a midstream natural-gas liquids pump station feeding a 400 km pipeline: two pump trains, a slug catcher, a metering skid, and an emergency-shutdown layer must all be supervised continuously, and any single-processor failure would take the station off-line and trigger a downstream delivery penalty. The classic answer on the Rockwell platform is a 1756-L65 redundancy pair — a primary and secondary Logix5565 controller in matching 1756 chassis, synchronised through a 1756-RM Redundancy Module over ControlNet, so that on primary failure the secondary assumes control bumplessly without a scan-time hiccup. This is the deployment pattern the 1756-L65 was positioned for: large enough in memory to carry a full station program with hundreds of PID loops and thousands of interlocks, yet efficient enough in chassis footprint (one slot in a 1756-A17) to leave room for the ENBT/CNBR/DNB communication mix that ties the station to the pipeline SCADA, the field DeviceNet instruments, and the local PanelView Plus HMI simultaneouslyindustrialmonitordirect.com+1.

 

Parameter

Main Parameters Value / Description
Product Model 1756-L65 (Logix5565 Processor)
Manufacturer Rockwell Automation / Allen-Bradley
Product Category ControlLogix 5560 Standard Controller (CPU)
User Memory 32 MB (data and logic)
I/O Memory 478 KB
Maximum Total I/O 128,000 points
Maximum Digital I/O 128,000 points
Maximum Analog I/O 4,000 points
Controller Tasks / Programs 32 tasks, 100 programs per task, event tasks supported
Controller Connections Up to 250
Built-In Ports RS-232 serial (DF1, ASCII, Modbus via logic, DH-485)
Network Support EtherNet/IP, ControlNet, DeviceNet, Remote I/O, DH+, SynchLink
Compatible Memory Card 1756-CF128 (128 MB CompactFlash)
Battery 1756-BA2 lithium, field-replaceable
Compatible Chassis 1756-A4, A7, A10, A13, A17
Current Draw 1200 mA @ 5.1 V DC, 14 mA @ 24 V DC
Power Dissipation / Heat 3.5 W / 11.9 BTU per hour
Operating / Storage Temperature 0 to 60 °C / −40 to +85 °C
Vibration / Shock 2 g @ 10–500 Hz / 30 g operating, 50 g non-operating
Weight ≈ 0.32 kg (Series A) / 0.35 kg (Series B)

 

 

Technical Principles and Innovative Values

  • Innovation Point 1 — Memory scaling on a common architecture. Within the 5560 family (1756-L61 through 1756-L65), the chassis, backplane, communication modules, and programming software are identical; only user memory and I/O capacity scale. Upgrading from a 1756-L61 (2 MB) to the 1756-L65 (32 MB) is a drop-in CPU swap with no change to chassis, I/O, or communication design — a deliberate Rockwell strategy that lets integrators right-size the controller to the program rather than re-architect the panel.
  • Innovation Point 2 — Multi-tasking with 32 prioritised tasks. The 1756-L65 executes up to 32 tasks and 100 programs per task, so continuous, periodic, and event-driven logic run as isolated scheduling domains. Critical safety-adjacent logic can run as a 10 ms periodic task while background housekeeping runs as a lower-priority continuous task — a design that isolates worst-case scan jitter without the programming gymnastics a single-task PLC requiresplchardware.com.
  • Innovation Point 3 — Bridge-module networking without CPU overload. Rather than embedding a fixed Ethernet port (as later 5580 controllers do), the 1756-L65 lets the engineer choose the communication mix — 1756-ENBT for EtherNet/IP, 1756-CNBR for redundant ControlNet, 1756-DNB for DeviceNet — and install them in the local chassis. The Logix backplane handles the bridge traffic, so the Logix5565 processor is free to scan logic while communication modules handle network protocol processing in parallelrockwellautomation.com+1.
  • Innovation Point 4 — Native bumpless redundancy. Paired with a 1756-RM Redundancy Module, the 1756-L65 delivers true synchronous redundancy: either controller can act as primary, switchover is bumpless in both directions, and the configuration is a checkbox in RSLogix 5000 rather than custom logic. Compared to legacy SLC 500 redundancy via the 1747-BSN, the ControlLogix approach removes the programming burden entirely and supports EtherNet/IP and ControlNet on the redundant backboneindustrialmonitordirect.com.
  • Innovation Point 5 — Battery-backed and CompactFlash non-volatile storage. A 1756-BA2 lithium battery preserves RAM contents through control-power loss, while the 1756-CF128 CompactFlash card provides non-volatile project and firmware storage for fast recovery — a two-layer persistence scheme that keeps the 1756-L65 productive in plants where an unplanned power dip cannot be allowed to wipe the running project

    Reviews

    There are no reviews yet.

    Be the first to review “Allen-Bradley 1756-L65 ControlLogix Processor – Logix5565 CPU with 32 MB User Memory”
    Review now to get coupon!

    Your email address will not be published. Required fields are marked *

    Back to Top

    Search For Products

    Product has been added to your cart