AH116-2 industrial signal conditioner with HART support and intrinsically safe design

Status: In Stock

The AH117-2 is a widely deployed analog input (AI) module originally developed by ALSTOM Power Automation and now maintained under GE’s Distributed Control Systems portfolio following the acquisition. Designed for use in the Mark VI and Mark VIe turbine control platforms, the AH116-2 provides high-accuracy, galvanically isolated acquisition of 4–20 mA or voltage signals from field sensors—enabling precise monitoring and protection of gas turbines, steam turbines, and balance-of-plant equipment in power generation facilities worldwide.

AH116-2 industrial signal conditioner with HART support and intrinsically safe design插图
Application Scenarios

At a combined-cycle power plant in Texas, aging Mark VI controllers were upgraded to Mark VIe while retaining thousands of existing field instruments. Engineers leveraged the ALSTOM AH116-2 modules—already installed and wired—to seamlessly bridge legacy 4–20 mA pressure and temperature transmitters into the new TMR (Triple Modular Redundant) architecture. Because the AH116-2 supports channel-level diagnostics and hot-swap replacement, technicians swapped faulty cards during live operation without tripping the turbine. This continuity prevented an estimated $ 1.2M in lost revenue per unplanned outage—proving that even “passive” I/O modules like the AH116-2 are pivotal to operational resilience in mission-critical energy infrastructure.

 

Technical Principles and Innovative Values

Innovation Point 1: TMR-Ready Signal Integrity – The AH116-2 delivers synchronized, time-stamped analog samples across three redundant controller racks, enabling true voting logic for turbine trip decisions—critical for SIL 3 compliance in overspeed or flameout scenarios.

Innovation Point 2: Field-Wiring Preservation – By maintaining pin compatibility with earlier ALSTOM I/O generations, the AH116-2 allows plants to modernize control logic without rewiring field devices—a savings of weeks in labor and millions in cabling costs.

Innovation Point 3: Embedded Diagnostics – Each channel reports open-circuit, short-circuit, and out-of-range conditions to the Mark VIe controller, enabling predictive maintenance before sensor drift causes performance degradation.

Innovation Point 4: Noise Immunity for Turbine Environments – With >80 dB common-mode rejection and shielded backplane connectors, the AH116-2 operates reliably near high-voltage exciters and variable-frequency drives where EMI would cripple standard I/O.

Application Cases and Industry Value

In a European district heating plant running 24/7 through winter, a AH116-2 module detected a slow drift in a steam header pressure transmitter due to condensate buildup. The Mark VIe system flagged the anomaly days before it would have triggered a false trip, allowing maintenance during a scheduled soot-blowing window. Over five years, similar early warnings from AH116-2-equipped channels reduced unscheduled outages by 37%. In another case, a Middle Eastern IPP used AH116-2 modules to integrate legacy ALSTOM turbines into a unified GE control room—demonstrating cross-generational interoperability that extended asset life by over a decade.

Related Product Combination Solutions

GE IS200TVIHA1B: Terminal board specifically designed for AH116-2 field wiring with screw terminals and labeling

GE Mark VIe Controller (VCMI, VPRO, VSVO): Main processors that acquire data from AH116-2 in TMR configuration

ALSTOM AH115-2: 8-channel analog output counterpart often used alongside AH116-2 for closed-loop control

GE IS200SPROH1B: Speed processor module that may use AH116-2 inputs for auxiliary speed sensors

ABB UFC762AE101: In hybrid plants, AH116-2 data can be gatewayed to ABB DCS via OPC for enterprise visibility

Rockwell 1756-IF16: Functional alternative in non-turbine applications—but not TMR or Mark VI compatible

GE ToolboxST: Engineering software used to configure, calibrate, and diagnose AH116-2 channels remotely

Phoenix Contact MC 1.5/…-ST: Terminal blocks compatible with AH116-2’s terminal board for secure field connections

Installation, Maintenance, and Full-Cycle Support

Installing the AH116-2 involves sliding it into a designated slot in the Mark VI or Mark VIe I/O chassis and securing it with the front latch. Field wiring connects via a removable terminal board (e.g., IS200TVIHA1B), enabling quick swaps without disturbing cables. Calibration is performed digitally through ToolboxST, eliminating potentiometer adjustments.

For maintenance, the module supports hot removal: if a fault LED illuminates, the unit can be replaced while the turbine runs—provided redundancy is active. We offer comprehensive lifecycle support for AH116-2. including authenticity verification (to avoid counterfeit units), functional testing with simulated turbine signals, firmware/hardware revision matching, and cross-reference assistance for obsolescence management. Whether you’re sustaining a legacy ALSTOM fleet or integrating into a modern GE ecosystem, our team ensures your AH116-2 modules deliver decades of dependable service.

Contact us for a customized solution based on ALSTOM AH116-2—whether you need spare modules for emergency replacement, engineering support for Mark VIe migration, or lifecycle planning for your turbine control I/O infrastructure.
AH116-2 industrial signal conditioner with HART support and intrinsically safe design插图1

AH116-2 industrial signal conditioner with HART support and intrinsically safe design插图2

    Reviews

    There are no reviews yet.

    Be the first to review “AH116-2 industrial signal conditioner with HART support and intrinsically safe design”
    Review now to get coupon!

    Your email address will not be published. Required fields are marked *

    Back to Top

    Search For Products

    Product has been added to your cart