The Allen-Bradley 1408-EM3A-ENT is the flagship energy monitoring device within the PowerMonitor 1000 series, representing the EM3 (Energy Monitor 3) configuration that consolidates all measurement capabilities of the transducer and energy monitor models into a single compact unit . As a comprehensive power monitoring solution, the Allen-Bradley 1408-EM3A-ENT measures voltage, current, frequency, power (kW, kVAR, kVA), true power factor, energy (kWh, kVARh, kVAh), and demand parameters including actual, projected, and power factor demand . This extensive parameter set positions the Allen-Bradley 1408-EM3A-ENT as the definitive choice for applications requiring complete energy visibility.

Manufactured by Rockwell Automation under the Allen-Bradley brand, the 1408-EM3A-ENT features an integrated Ethernet port supporting both EtherNet/IP and Modbus TCP protocols, alongside an RS-485 serial interface for DF1 Full/Half-Duplex and Modbus RTU communications . This dual-communication architecture enables seamless integration with existing Allen-Bradley PLC platforms including PLC-5, SLC, and ControlLogix families, as well as SCADA and energy management software such as RSEnergyMetrix and FactoryTalk EnergyMetrix .

The Allen-Bradley 1408-EM3A-ENT is designed for panel or DIN rail mounting, featuring an integrated LCD display for local data viewing and configuration. With revenue meter accuracy classified under EN62053-21:2003 and UL/cUL/CE certifications, this energy monitor delivers the precision and reliability demanded for cost allocation, load profiling, and energy optimization initiatives in industrial and commercial facilities .

Allen-Bradley 1408-EM3A-ENT | EM3 Series Power Monitor with Dual Communication插图

 

Technical Specifications

Parameter Name Parameter Value
Product Model 1408-EM3A-ENT
Manufacturer Allen-Bradley / Rockwell Automation
Product Type Energy Monitor (EM3 Series)
Series PowerMonitor 1000
Control Power 85…264V AC, 47…63 Hz (2.5 VA max) or 125…250V DC (4 VA max)
Voltage Sense Inputs V1, V2, V3; Input Impedance: 5 MΩ min; Input Current: 2 mA max
Current Sense Inputs I1, I2, I3; 5A RMS nominal; Overload: 15A continuous, 200A for 0.5s
Communication Protocols EtherNet/IP, Modbus TCP, DF1 Full/Half-Duplex, Modbus RTU, DH-485
Ethernet Port Integrated, ODVA EtherNet/IP Conformance Tested (Version A2.8)
Serial Port RS-485
Display Integrated LCD
Status Inputs Two, contact closure (internal 24V DC)
KYZ Output Configurable; 30 mA at 240V AC / 300V DC
Operating Temperature -10…60 °C (14…140 °F)
Storage Temperature -40…85 °C (-40…185 °F)
Humidity 5…95%, non-condensing
Mounting Panel or DIN Rail
Certifications UL, cUL, CE; EN62053-21:2003 Class 1 accuracy

 

Main Features and Advantages

Complete Energy Monitoring Capability: The Allen-Bradley 1408-EM3A-ENT combines all measurement functions of the PowerMonitor 1000 product family, delivering voltage, current, frequency, power (kW/kVAR/kVA), true power factor, energy (kWh/kVARh/kVAh), and demand analysis (actual, projected, and power factor) in a single device . This comprehensive parameter set eliminates the need for multiple monitoring instruments, reducing installation cost and panel space requirements.

Revenue-Grade Accuracy: With metering accuracy classified under EN62053-21:2003 for power functions and Class 1 requirements for energy functions, the 1408-EM3A-ENT provides the precision necessary for billing and sub-billing applications . Voltage and current sensing inputs maintain ±0.5% accuracy at 25°C, ensuring reliable data for cost allocation and energy management decisions.

Dual Communication Flexibility: The Allen-Bradley 1408-EM3A-ENT supports both Ethernet (EtherNet/IP, Modbus TCP) and serial (RS-485: DF1 Full/Half-Duplex, Modbus RTU, DH-485) communications . This dual-protocol capability enables integration with existing control systems, SCADA platforms, and energy management software without requiring additional gateway hardware.

Comprehensive Logging and Diagnostics: The 1408-EM3A-ENT maintains energy logs, minimum/maximum logs, load factor logs, and status logs for historical analysis and troubleshooting . Wiring diagnostics provide verification of proper installation, while Time of Use (TOU) logging supports on-peak and off-peak energy analysis for demand response strategies.

Integrated Display and Local Configuration: An onboard LCD display allows technicians to view real-time data and configure parameters without external software, simplifying commissioning and maintenance . Panel or DIN rail mounting options accommodate diverse installation requirements in electrical enclosures and control panels.