BENTLY 1900-65A Industrial Machinery Health Protection Monitor

Status: In Stock

BENTLY Nevada 1900-65A is a cost-effective general-purpose equipment monitor, designed for continuous vibration, position, speed and temperature monitoring of rotating machinery. It supports multi-type sensor inputs, dual-level alarms and Modbus communication, ideal for auxiliary equipment protection in power, oil & gas and manufacturing.

Supply Voltage: 18–36 VDC

Operating Temperature: -40°C ~ +70°C

Input Channels: 4 vibration/position, 4 temperature

Outputs: 6 relays, 4×4–20mA, 1 buffered output

Communication: Modbus TCP/RTU, Ethernet/RS485

BENTLY 1900-65A Industrial Machinery Health Protection Monitor插图

1900-65A Product Overview

BENTLY Nevada 1900-65A belongs to the BENTLY 1900 series general-purpose equipment monitor, a core component for non-critical rotating machinery health monitoring (now under Baker Hughes). It’s built for pumps, fans, compressors, motors and auxiliary equipment across power generation, oil & gas, water treatment and cement plants, delivering reliable real-time status monitoring and fault protection.1900-65A integrates 4 configurable vibration/position/speed channels and 4 temperature channels, supporting proximity probes, accelerometers, velocity sensors, thermocouples and RTDs. With 24-bit A/D conversion and 25kHz bandwidth, it ensures high-precision signal acquisition. BENTLY 1900-65A features independent Alert/Danger alarms, programmable relays and buffered outputs, enabling seamless integration with DCS, PLC and SCADA systems via Modbus—truly a cost-effective solution for predictive maintenance and equipment protection.

 

1900-65A Technical Specifications

Parameter Value
Product Model 1900-65A (173401-01)
Manufacturer BENTLY Nevada (Baker Hughes)
Product Type General Purpose Equipment Monitor
Vibration Inputs 4 channels: 2/3-wire accelerometer, velocity, proximity probe
Temperature Inputs 4 channels: E/J/K/T thermocouple, 2/3-wire RTD
Supply Voltage 18–36 VDC (optional 110/220 VAC)
A/D Converter 24-bit, 25 kHz bandwidth
Alarm Levels Dual: Alert (warning) + Danger (trip)
Relay Outputs 6 configurable relay outputs
Analog Outputs 4×4–20 mA recorder outputs
Buffered Output 1 dedicated transducer signal buffer
Communication Modbus TCP/RTU, Ethernet, RS232/RS485
Operating Temp -40°C ~ +70°C, 5–95% RH (non-condensing)
Mounting DIN rail / panel mount
Dimensions 196.9×149.4×74.4 mm
Weight 0.77 kg
Certifications ATEX/IECEx, FCC, Class I Div 2

 

Key Features and Advantages

BENTLY 1900-65A stands out with its flexible sensor compatibility and high cost-performance—no fancy frills, just rock-solid monitoring for auxiliary machines. Each of the 4 vibration channels supports independent configuration for vibration (velocity/acceleration), position (gap) or speed, with adjustable filters and full-scale ranges, adapting to different sensor types and measurement needs. The 4 temperature inputs cover all common thermocouple and RTD types, unifying vibration and thermal monitoring in one module.It uses 24-bit high-resolution ADC (analog-to-digital converter) and 25kHz wide bandwidth, capturing weak fault signals accurately and reducing false alarms. Dual independent Alert/Danger setpoints let you set early warning and trip thresholds separately, balancing protection and uptime. Six programmable relay outputs can be mapped to any channel or combination, triggering alarms, shutdowns or bypass as needed—fully customizable for site logic.1900-65A supports Modbus TCP/RTU over Ethernet and RS485, easily connecting to upper control systems for remote data access and centralized monitoring. The buffered output preserves raw transducer signals for offline analysis, supporting predictive maintenance. With ATEX/IECEx hazardous area certification and wide temperature tolerance, BENTLY 1900-65A operates stably in harsh industrial environments, with minimal maintenance and long MTBF (mean time between failures).

 

BENTLY 1900-65A Industrial Machinery Health Protection Monitor插图1

Application Areas

BENTLY 1900-65A is the go-to monitor for auxiliary rotating equipment across all heavy industries—where you need reliable monitoring without the cost of high-end system monitors. In power plants, it protects cooling tower fans, boiler feed pumps, condensate pumps, fans and small hydro turbines, monitoring vibration and bearing temperature to prevent unexpected failures and maintain plant auxiliary system stability.In oil & gas and petrochemical facilities, 1900-65A monitors centrifugal pumps, reciprocating compressors, blowers and agitators, detecting early signs of bearing wear, rotor imbalance and misalignment—critical for avoiding unplanned shutdowns in refineries and chemical plants. It’s also widely used in water treatment, pulp & paper, mining and cement industries, monitoring motors, conveyors and process equipment, providing real-time health data for predictive maintenance schedules.For OEM equipment and system retrofits, BENTLY 1900-65A offers a compact, easy-to-integrate solution. Its universal sensor support and Modbus connectivity let it fit into existing control architectures, upgrading equipment monitoring from basic to intelligent without major system overhauls—perfect for balancing cost and reliability in auxiliary asset management.

 

Related Products

  1. 1900-60A: Base model of 1900 series, basic vibration monitoring without temperature inputs
  2. 1900-65B: Enhanced version with more I/O and advanced communication options
  3. 1900-70A: Multi-channel monitor for larger auxiliary equipment groups
  4. 330180: BENTLY proximity probe, matching sensor for 1900-65A vibration measurement
  5. 1900-05-00-00: Configuration display module for 1900-65A on-site setup
  6. 1900-65A-01: DIN-rail mounted variant with integrated display
  7. 173089: Power supply module for 1900-65A
  8. BENTLY 3500 Series: High-end system monitors for critical turbomachinery, complementary to 1900-65A

 

Installation and Maintenance

Installation Preparation: Before installing BENTLY 1900-65A, confirm sensor types (vibration/temperature) and wiring specs, select DIN rail or panel mounting. Ensure 18–36 VDC stable power supply, separate sensor signal cables from power/control cables to avoid EMI interference. Mount the module in a well-ventilated location, connect vibration/temperature inputs correctly, set sensor parameters (type, range, filters) via configuration software, and verify alarm setpoints and relay logic before power-on commissioning.Maintenance Suggestions: 1900-65A is designed for long-term, low-maintenance operation. Regularly check front-panel status LEDs (OK/Alert/Danger) and communication indicators; inspect terminal connections for looseness and dust buildup monthly. Every 6 months, perform sensor calibration and alarm threshold verification, backup configuration parameters to non-volatile memory. Avoid hot-plugging; replace faulty modules only after powering down. Keep the environment dry and dust-free to ensure stable long-term performance of BENTLY 1900-65A.

BENTLY 1900-65A Industrial Machinery Health Protection Monitor插图2

    Reviews

    There are no reviews yet.

    Be the first to review “BENTLY 1900-65A Industrial Machinery Health Protection Monitor”
    Review now to get coupon!