GE 745-W3-P5-G5-HI-A-L-R-E-H Draw-Out Numerical Transformer Protection Relay with Conformal Coating

Status: In Stock

Product Overview

The GE Multilin 745-W3-P5-G5-HI-A-L-R-E-H​ is a high-speed, microprocessor-based transformer management relay from the GE Multilin 745 Transformer Protection System family, today supported under the GE Vernova Grid Solutions portfolio. It is engineered as a single-device answer to the protection, control, metering and asset-monitoring needs of small, medium and large power transformers, autotransformers and shunt reactors, and it can be applied as either primary protection or backup protection on two-winding, three-winding and breaker-and-a-half source terminal arrangements. At its core, the 745-W3-P5-G5-HI-A-L-R-E-H​ executes dual-slope percentage differential protection with adaptive harmonic restraint across three windings per phase, supported by restricted ground fault, phase and ground overcurrent, overexcitation (V/Hz), under/over-frequency, negative-sequence and thermal overload elements.Decoding the order code reveals a fully loaded configuration. W3 denotes three windings per phase; P5 and G5 specify 5 A phase and 5 A ground current inputs; HI defines the wide-range 90 to 300 V DC / 70 to 265 V AC control power supply; A adds analog inputs and outputs; L enables transformer loss-of-life monitoring; R adds restricted ground fault protection; E selects the enhanced 40-character LCD; and H applies harsh-environment conformal coating. This makes the GE 745-W3-P5-G5-HI-A-L-R-E-H​ a genuine “specify once, install anywhere” variant for retrofit projects where substation battery voltage, CT secondary rating and ambient conditions vary from bay to bay.Beyond protection, the 745-W3-P5-G5-HI-A-L-R-E-H​ integrates revenue-grade metering, harmonics analysis to the 21st, IRIG-B time synchronisation, event recording, oscillography and a data logger, and it exposes all of it over Modbus RTU, Modbus TCP/IP and DNP 3.0. Combined with FlexLogic programmable logic, a draw-out case and the EnerVista 745 Setup software suite, the relay replaces the stack of separate electromechanical relays, transducers and meters that traditional transformer panels used to require, cutting panel space, wiring and commissioning time while giving protection engineers a single, auditable settings file.

GE 745-W3-P5-G5-HI-A-L-R-E-H Draw-Out Numerical Transformer Protection Relay with Conformal Coating插图

 

Technical Specifications

Parameter Name Parameter Value
Product Model 745-W3-P5-G5-HI-A-L-R-E-H
Manufacturer GE Multilin (GE Vernova Grid Solutions)
Product Type Transformer Management Relay / Numerical Differential Protection Relay
Series / Platform 745 Transformer Protection System (SR745)
Windings per Phase W3 = three windings per phase
Phase Current Input P5 = 5 A (Winding 1, Winding 2, Winding 3)
Ground Current Input G5 = 5 A (Winding 1/2, Winding 2/3)
Control Power HI = 90 to 300 V DC; 70 to 265 V AC at 48 to 62 Hz (30 VA nominal, 40 VA max)
Nominal Frequency 50 / 60 Hz (frequency tracking from 2 to 65 Hz)
Voltage Input 60 to 120 V phase-to-neutral, max. continuous 273 V, burden < 0.025 VA at 120 V
Current Input Burden < 0.2 VA per phase at rated; withstand 1 s at 80× rated, continuous at 3× rated
Logic Inputs 16 programmable (dry: 1000 Ω max ON at 32 V DC; wet: 30 to 300 V DC)
Output Relays 8 output relays (Form A on 2–5, Form C on 6–8 and self-test) plus 1 solid-state SCR trip output
Analog Outputs 7 channels, programmable 0–1 / 0–5 / 0–10 / 0–20 / 4–20 mA (600 Ω max load at 4–20 mA)
Analog Input / RTD / Tap DC mA input (375 Ω ±10%); 3-wire RTD (100 Ω Pt, 100 Ω Ni, 120 Ω Ni); tap position 0–500 Ω or 0.5–5.0 kΩ
Communication Front RS232, rear RS485/RS422, optional 10Base-T Ethernet; Modbus RTU, Modbus TCP/IP, DNP 3.0 Level 2; IRIG-B
Event & Disturbance Records 128 time-tagged events; oscillography 10 records up to 32 power cycles (64 samples/cycle)
Operating Temperature −40 °C to +60 °C (storage −40 °C to +85 °C); humidity up to 90% non-condensing
Dimensions / Weight Approx. 229 × 181 × 178 mm (9″ H × 7⅛” W × 7″ D); approx. 4.8 kg
Mounting Draw-out case, 19″ rack or flush panel mount; front IP40, rear IP20
Enclosure Option H = harsh (chemical) environment conformal coating
Standards IEC 60255, IEEE C37.90, CE, UL/cUL

 

Main Features and Advantages

Adaptive harmonic restraint for secure energisation: The GE Multilin 745-W3-P5-G5-HI-A-L-R-E-H​ implements dual-slope percentage differential protection with three user-selectable restraint methods, combining conventional and adaptive second-harmonic blocking with fifth-harmonic inhibition. This lets the relay distinguish magnetising inrush and overexcitation from genuine internal winding faults, so the transformer can be energised confidently without desensitising the differential element. Pickup is adjustable from 0.05 to 1.00 × CT with independent slope-1 (15–100%) and slope-2 (50–100%) settings and a programmable knee point, and restraint is derived from maximum winding current for exceptional through-fault stability under CT saturation.Three-winding coverage in one chassis: Because the 745-W3-P5-G5-HI-A-L-R-E-H​ is configured for three windings per phase with 5 A CT inputs on every winding and both ground inputs, a single relay protects three-winding transformers and autotransformers that would otherwise need two or more differential relays plus interposing CTs. Dynamic CT ratio mismatch correction works hand in hand with the tap-position input to keep the differential balance accurate as the on-load tap changer moves through up to 50 positions.Restricted ground fault and loss-of-life in one unit: The R option gives the 745-W3-P5-G5-HI-A-L-R-E-H​ sensitive restricted ground fault detection for winding-to-ground faults near the neutral, while the L option continuously computes hottest-spot temperature, ageing factor and loss-of-life percentage. Maintenance teams gain a live view of insulation consumption rather than a guess, which directly supports condition-based maintenance and deferral of capital replacement.Built for the field, not just the panel: The H conformal coating protects internal boards against humidity and chemical contamination, the draw-out case allows relay replacement without disturbing CT and VT wiring, and FlexLogic lets engineers build interlocks, breaker-failure schemes and custom alarm matrices without external auxiliary relays. Sixteen logic inputs accept dry or wet contacts, seven isolated analog outputs feed DCS and SCADA trends, and IRIG-B time synchronisation aligns event records across the substation so post-fault analysis is unambiguous.

Application Field

Utility transmission and distribution substations: The GE Multilin 745-W3-P5-G5-HI-A-L-R-E-H​ is most often specified as the main differential protection for HV/MV power transformers from roughly 11 kV through transmission class, including three-winding units and autotransformers with a tertiary winding. Its three-winding differential zones replace legacy electromechanical or static relays during substation refurbishment, and the draw-out case keeps replacement time to minutes during outages.Heavy industry and process plants: Steel mills, cement works, chemical complexes, refineries and mining operations deploy the 745-W3-P5-G5-HI-A-L-R-E-H​ on incoming and unit transformers feeding large drives, furnace transformers and rectifier transformers. Here the conformal-coated variant matters: sulphur-rich, humid or dusty atmospheres that destroy standard electronics are tolerated, while harmonics analysis to the 21st helps engineers quantify the distortion produced by variable-speed drives and rectifiers before it overheats the transformer.Generation, renewables and grid interconnection: Power-plant unit and station-service transformers, wind-farm collector transformers and solar PV step-up transformers all benefit from the sensitive differential element with inrush blocking, plus overexcitation (V/Hz) protection that guards the core during load rejection or weak-grid voltage excursions. The GE 745-W3-P5-G5-HI-A-L-R-E-H​ also integrates easily into digital substation architectures, feeding measurements, alarms and oscillography to SCADA, DCS and plant asset-management systems over Modbus, DNP 3.0 or Ethernet, which removes the separate transducer and meter layer.Critical infrastructure: Data centres, hospitals, rail traction substations and water-treatment facilities use the 745-W3-P5-G5-HI-A-L-R-E-H​ where an unprotected transformer failure is unacceptable. In these settings the loss-of-life and hottest-spot monitoring functions are as valuable as the tripping functions, because they let operators load the transformer closer to its true thermal limit with evidence rather than conservatism.

GE 745-W3-P5-G5-HI-A-L-R-E-H Draw-Out Numerical Transformer Protection Relay with Conformal Coating插图1

    Reviews

    There are no reviews yet.

    Be the first to review “GE 745-W3-P5-G5-HI-A-L-R-E-H Draw-Out Numerical Transformer Protection Relay with Conformal Coating”
    Review now to get coupon!

    Your email address will not be published. Required fields are marked *

    Back to Top

    Search For Products

    Product has been added to your cart