ABB AO810V2 Analog Output Module – 14-Bit Resolution, ±0.1% Accuracy, OSP Fail-Safe on ModuleBus Loss

Status: In Stock

Product Overview

The ABB AO810V2​ (order No. 3BSE038415R1) is an 8-channel analog current output module in ABB’s S800 I/O family, designed to sit on a terminal unit (MTU) such as TU810, TU812, TU814, TU830 or TU833, and communicate with an AC800M, AC800F, or Freelance controller over the ModuleBus backplane. Its core job is straightforward but critical: take the controller’s internal digital setpoint—valve position, VFD speed reference, burner tilt, damper command—convert it via 14-bit DAC to a standard 0–20 mA or 4–20 mA current loop, and drive up to 500 Ω (L1+ feed) or 250–850 Ω (L2+ feed) of field load per channel. At ≤2 ms update cycle and ±0.1% full-scale accuracy (0–500 Ω), the ABB AO810V2​ hits the performance bracket that continuous-process loops—pulp-stock valve, gas-fuel split-range, reactor-feed VFD—actually care about, without stepping up to the HART-capable AO815 or AO820 tier.Physically the AO810V2​ is a compact 45 × 119 × 102 mm (≈0.18–0.2 kg) S800 slice, keying code AE​ so it cannot be accidentally seated in a DI/DO/AI MTU position—an underrated feature during cabinet rework when someone grabs the wrong module at 2 a.m. The V2 revision over the original AO810 tightens EMI immunity and sharpens the open-circuit diagnostic threshold (channel faults when current >1 mA and no valid load), which is why most procurement specs now call out “-V2” explicitly rather than the bare AO810. It is not HART-enabled, not channel-to-channel isolated (8 ch share one ground reference, group-isolated from earth), and not redundant—three honest limitations to state up front so the buyer doesn’t spec it into a HART multivariable or Ex-i loop where AO815/AO820 belong.In the ABB ecosystem the ABB AO810V2​ is the workhorse “non-HART AO” slot: every S800 rack that drives ten control valves but doesn’t need HART feedback ends up with two or three of these. For MRO planners on plants standardized to AC800M / 800xA / Freelance with S800 remote I/O, keeping AO810V2​ on the shelf covers 80% of AO failure tickets without paying HART-module pricing. And because it hot-swaps (when the MTU and system config allow it), a failed channel rarely forces a process trip—slide the old one out, slide the new ABB AO810V2​ in, re-key, and the loop is back.

ABB AO810V2 Analog Output Module – 14-Bit Resolution, ±0.1% Accuracy, OSP Fail-Safe on ModuleBus Loss插图

 

Technical Specifications

Parameter Name Parameter Value
Product Model AO810V2
Order Number 3BSE038415R1
Manufacturer ABB
Product Type Analog Output Module, S800 I/O
Number of Channels 8, single-ended, group-isolated (group to earth)
Signal Type 0–20 mA / 4–20 mA (software-selectable per channel)
Resolution 14 bit + sign
Accuracy Max. 0.1% of span (0–500 Ω load)
Update Cycle Time ≤ 2 ms
Output Load ≤ 500 Ω (supply on L1+ only); 250–850 Ω (supply on L2+ only)
Load Type Short-circuit proof, current-limited
Open-Circuit Detection Yes, when setpoint > 1 mA (channel error reported)
Overrange –15% / +15%
Temperature Drift Typ. 30 ppm/°C, max. 60 ppm/°C
Rise Time 0.35 ms @ 500 Ω
Max. Field Cable Length 600 m
Isolation Groupwise isolated from ground (channels share common reference)
Rated Insulation Voltage 50 V
Dielectric Test 500 V a.c.
Power Dissipation Typ. 2.3 W
Current Consumption +5 V ModuleBus: max. 70 mA; +24 V external: 245 mA
Communication ModuleBus (to AC800M / 800xA / Freelance)
HART No
Redundancy No
SOE No
Intrinsic Safety No
MTU Compatibility TU810, TU812, TU814, TU830, TU833
Keying Code AE
Hot Swap Yes (with MTU support & system configuration enabled)
Front LEDs F (Fault, red), R (Run, green), W (Warning, yellow), O (Output state)
Diagnostics Module error, output power low, open-circuit per channel
Operating Temp. 0 °C to +55 °C (vertical mount in compact MTU: max +40 °C)
Storage Temp. –40 °C to +70 °C
Humidity 5–95% RH, non-condensing
Pollution Degree 2 (IEC 60664-1)
Protection IP20
Certifications CE, cULus C1 Div 2, ATEX Zone 2, ABS / BV / DNV / LR, RoHS, WEEE
Dimensions (W×H×D) 45 × 119 × 102 mm (111 mm with connector)
Weight ≈0.18–0.2 kg

 

Main Features and Advantages

14-bit resolution with ≤2 ms refresh in a non-HART price tier.​ The ABB AO810V2​ lands in the sweet spot: accurate enough for PID valve loops and VFD speed setpoints in refineries, pulp-mill stock lines, and boiler auxiliary control, without the cost adder of HART. Most continuous-process AO loops don’t need HART write—they need stable current drive and fast update, which the AO810V2​ delivers at 0.35 ms rise time and 600 m field-cable headroom.OSP (Output Set Point) on communication loss.​ If ModuleBus drops or the controller goes dark, the ABB AO810V2​ can be pre-configured to drive each channel to a safe state—hold last, clamp to zero, or jump to a user-defined mA value. For a fired-heater fuel-air split-range or a reactor-feed control valve, that “don’t go wild when the rack blips” behavior is what keeps the DCS engineer sleeping at night. OSP is a software-grouped feature, but the hardware has to support it—and the AO810V2​ does.Open-circuit diagnostics that actually catch loose terminations.​ The >1 mA threshold is deliberate: if the controller is asking for 12 mA and the module sees no load-path integrity, it throws a channel error instead of silently driving a dead loop. In plants where “valve not moving” tickets take two hours to trace to a corroded terminal on a marshalling cabinet 40 metres away, the ABB AO810V2​ diagnostic saves that walk. The front-panel O (output state) LED per channel also lets a tech confirm “am I actually driving?” without a clamp meter.L2+ supply extends to 850 Ω.​ This is the practical differentiator versus modules that cap at 500 Ω. Run a 4–20 mA loop through 300 m of 1.5 mm² paired cable plus a 250 Ω receiver shunt plus a surge isolator, and you’ll thank the AO810V2​ for the L2+ headroom—especially in greenfield sites where the marshalling cabinet and field instrument aren’t in the same building.Keying AE prevents wrong-slot insertion.​ S800 MTUs accept multiple module types, and the mechanical keying between AO810V2​ (AE) and, say, a DI810 (different keying) stops a tired electrician from forcing an AO into a DI position and cooking the rail. Small detail, big MRO value.Honest limitations stated upfront.​ The ABB AO810V2​ is not HART-capable (that’s AO815/AO820), not channel-to-channel isolated (8 ch share a return—fine for most valve/VFD loops, wrong for differential pH / conductivity pairs that need galv isolation), and not redundant. If your loop needs HART or channel isolation, step up; if it just needs 8 solid mA outputs, the AO810V2​ is the right SKU and the V2 suffix is the one to stock—original AO810 is functionally close but EMI/diagnostic tuning on V2 is why most service BOMs migrated.

 

Application Field

The ABB AO810V2​ sits in S800 I/O racks that serve AC800M, 800xA, and Freelance controller platforms, which puts it across the usual ABB DCS install base: oil & gas gathering stations driving pneumatic-positioner valves on separator dump/cut lines; refinery tank-farm blend skids where 4–20 mA feeds VFD speed references on transfer pumps; pulp & paper stock-prep lines where stock-throttling valves and refiner dilution water valves hang off S800 remote I/O in the machine-room rack; power-gen balance-of-plant—coal-mill primary-air damper, gas-turbine aux boiler drum-level valve, FD fan inlet-vane VFD reference—all classic AO810V2​ loads because none of them need HART back-channel, just stable 4–20 mA with OSP on comms loss.Water & wastewater is another dense pocket: chemical-dose metering pumps (0–20 mA for stroke-speed), UV-reactor bypass-damper actuators, dissolved-air-floatation skimmer VFDs—these tend to land in compact MTU (TU810/TU814) S800 slices in outdoor-rated kiosks, and the ABB AO810V2​ 0–55 °C rating plus C1D2 / ATEX Zone 2 certification covers most non-classified and light-hazard kiosks without stepping to the premium AO815. Marine and offshore MCC bays that carry ABS/BV/DNV/LR type approval on the S800 rack also use the AO810V2​ for non-HART actuator loops—ballast valve, seawater cooling modulation, generator lub-oil cooler bypass—where the 600 m cable length and 850 Ω L2+ load matter because the MTU is in the ECR and the actuator is on deck. Across all of these, the problem pattern is the same: controller has the number, field needs the mA, and the AO810V2​ is the eight-lane bridge that doesn’t need HART to do its job.

    Reviews

    There are no reviews yet.

    Be the first to review “ABB AO810V2 Analog Output Module – 14-Bit Resolution, ±0.1% Accuracy, OSP Fail-Safe on ModuleBus Loss”
    Review now to get coupon!

    Your email address will not be published. Required fields are marked *

    Back to Top

    Search For Products

    Product has been added to your cart