Siemens 6DS1300-8AB MKI Monitor/Keyboard Interface Module — VGA + PS/2 Bridge for SICOMP C30/C35 Industrial PC Racks

Status: In Stock

Product Overview

The Siemens 6DS1300-8AB​ is the MKI (Monitor/Keyboard Interface) module within Siemens’ SICOMP industrial PC family, specifically engineered for the SICOMP C30 and C35 operator-station racks that powered countless control-room HMI seats in Teleperm M and early SPPA-T3000 environments. In these cabinets, the SICOMP CPU board routes graphics and keyboard-controller traffic over the internal proprietary backplane, but the rack’s front or rear panel offers no standard video or keyboard cutouts. The Siemens 6DS1300-8AB​ plugs into a single Eurocard slot in the PCA 500 or PCA 700 rack, picks up that backplane traffic, and breaks it out to a standard VGA DB15 connector plus dual PS/2 mini-DIN sockets for keyboard and mouse at the rack rear. This lets a plant retire Siemens’ proprietary (and long end-of-life) operator terminals and instead drive a commercial-off-the-shelf 17″ CRT or LCD monitor with a normal PS/2 keyboard—an ergonomics and sparing leap that many plants implemented during mid-life upgrades of C30/C35 consoles in the 2000s.Architecturally, the Siemens 6DS1300-8AB​ is a passive, buffer-level passthrough rather than an active graphics accelerator; it carries no firmware the OS depends on, which means it is a zero-configuration drop-in—seat it, connect the monitor and keyboard, and the existing SICOMP OS image (often OS 235/252 or a WinCC/POS flavor on SICOMP) sees the peripherals exactly as it would a native Siemens terminal. Power comes from the rack backplane at +5 V DC, with typical dissipation around 2 W, so the card adds negligible thermal load to already-dense operator-station racks. Its shielding and industrial-grade component selection are aimed at the electrically noisy environment behind a DCS console, where relay switching, printer motors, and adjacent VFD-fed auxiliaries can inject noise onto unbalanced video and keyboard lines if the interface isn’t properly buffered.Although Siemens has long since transitioned operator-station hardware to SIMATIC Rack PCs and modern thin-client architectures, the installed base of C30/C35 consoles—especially in power-generation unit cabins, turbine-local panels, and legacy Teleperm M control rooms that have not yet undergone a full DCS migration—remains sizable. For those plants, the Siemens 6DS1300-8AB​ is not a nice-to-have spare; it is the only correct bridge module to keep a failing proprietary-monitor setup from forcing an unplanned HMI outage. Stocking even one cold-spare per control-room row is standard practice in life-extension programs for 1990s–2000s SICOMP fleets.

Siemens 6DS1300-8AB MKI Monitor/Keyboard Interface Module — VGA + PS/2 Bridge for SICOMP C30/C35 Industrial PC Racks插图

 

Technical Specifications

Parameter Value
Product Model 6DS1300-8AB
Manufacturer Siemens (SICOMP industrial PC family)
Product Type Monitor/Keyboard Interface Module (MKI)
Compatible System SICOMP C30 / C35 operator stations; PCA 500 / PCA 700 racks
Video Output 1 × VGA (DB15 female)
Keyboard Port 1 × PS/2 (mini-DIN 6-pin)
Mouse Port 1 × PS/2 (mini-DIN 6-pin)
Backplane Bus SICOMP proprietary (graphics + KBC traffic)
Supply Voltage +5 V DC (from SICOMP rack backplane)
Power Dissipation ~2 W typical
Mounting Single-slot Eurocard (PCA 500 / PCA 700)
Dimensions (approx.) 100 × 160 mm (single-width)
Operating Temperature 0 °C to +55 °C
Storage Temperature –25 °C to +70 °C
Relative Humidity 5 % to 95 % (non-condensing)

 

Main Features and Advantages

COTS-peripheral bridge in a proprietary rack.​ The core value of the Siemens 6DS1300-8AB​ is that it ends the proprietary-terminal dependency. SICOMP C30/C35 consoles were originally sold with Siemens-branded CRT operator terminals—low resolution by modern standards, expensive when they failed, and long since discontinued. The MKI card intercepts the CPU’s graphics and keyboard streams on the backplane and re-presents them on standard connectors, so a plant can spec a commodity 1280×1024 LCD and a tactile PS/2 keyboard from any office supplier. For a control room with six to twelve operator seats, that substitution pays for the Siemens 6DS1300-8AB​ cards many times over across a refurbishment cycle.Passive, zero-configuration drop-in.​ Unlike an active graphics adapter that needs driver validation, EDID handshakes, and firmware alignment, the Siemens 6DS1300-8AB​ is essentially a buffered PHY-level passthrough. There is no firmware for the OS to load and no jumper block to set. Seat the card in the PCA 500/700 slot that the SICOMP hardware configuration reserves for “MKI,” connect the VGA cable and PS/2 keyboard (and mouse, if the OS image supports it), and the existing Teleperm/SICOMP OS boots exactly as before. This matters during unplanned failures—an operator-station monitor goes dark on a weekend, the tech swaps in a Siemens 6DS1300-8AB​ and a new LCD, and the console is live again inside the next reboot without touching DCS downloads.Shielded, noise-immune signal path.​ Control-room console cabinets share space with relay panels, printer loads, and occasionally VFD-fed motor feeders for roller-shutter doors or local ventilators—all sources of conducted and radiated noise that can turn into “snow” on video or ghost-key repeats on cheap interface cards. The Siemens 6DS1300-8AB​ uses shielded internal routing and industrial-grade buffering on both the VGA RGBHV lines and the PS/2 bidirectional data/clock pairs, so the picture stays flicker-free and keystrokes arrive deterministic even in an uncorrected electrical environment. For plants that kept C30/C35 consoles close to turbine-deck MCC rows, this shielding is the difference between a usable console and a technician complaining about “the keyboard is acting up again.”Single-slot, low-power economy.​ At ~2 W drawn from the +5 V backplane rail, the Siemens 6DS1300-8AB​ adds almost nothing to the rack’s 24 V / 5 V distribution budget. It occupies exactly one Eurocard position in the PCA 500/700, leaving the rest of the slot budget for CPU, memory, disk, and communications modules. In C30/C35 configurations where slot count is already tight (typical build: CPU + RAM + MKI + floppy/hard-disk interface + possibly a PROFIBUS or 20 mA current-loop card), that single-slot footprint matters.Legacy continuity for deferred-migration plants.​ Many fossil and combined-cycle units commissioned in the late 1990s to early 2000s still run Teleperm M or early SPPA-T3000 with SICOMP C30/C35 desks in the unit cabin. A full DCS-and-operator-station migration is a multimillion-euro, multi-week outage project. Until budget and schedule align, the Siemens 6DS1300-8AB​ is the sanctioned way to keep those desks viable—swap failing proprietary monitors for LCDs, keep PS/2 keyboards in stock (they are still manufactured for industrial POS use), and defer the HMI rebuild by another five to eight years without compromising control-room operability.

Siemens 6DS1300-8AB MKI Monitor/Keyboard Interface Module — VGA + PS/2 Bridge for SICOMP C30/C35 Industrial PC Racks插图1

    Reviews

    There are no reviews yet.

    Be the first to review “Siemens 6DS1300-8AB MKI Monitor/Keyboard Interface Module — VGA + PS/2 Bridge for SICOMP C30/C35 Industrial PC Racks”
    Review now to get coupon!

    Your email address will not be published. Required fields are marked *

    Back to Top

    Search For Products

    Product has been added to your cart