Application Scenarios
In a 600 MW supercritical coal-fired unit commissioned in the late 1990s, the original Bailey INFI 90 DCS is still in production control, but the plant’s new asset-management and performance-computing layer runs on a modern Windows server that has to sample 8,000+ process points every scan cycle. Without a reliable Cnet-to-computer interface, the only route would be to hand-pick values from operator console exports — slow, error-prone, and unusable for closed-loop optimization. By placing an INICT13A Infi-Net to Computer Transfer Module in the same Harmony cabinet as the existing INNIS01, wiring the 60-pin ribbon to an IMMPI01, and landing on an NTMP01 termination unit that feeds the OPC server, the integration team gives the historian and the optimization package a first-class, point-addressed, exception-reported data source straight off the INFI-NET ring. The INICT13A becomes the single point of contact between the legacy DCS and the modern IT layer — exactly the role it was designed forinfi90.com+1.
Parameter
| Main Parameters | Value / Description |
|---|---|
| Product Model | ABB Bailey INICT13A |
| Manufacturer | ABB (Bailey Controls / Elsag Bailey Process Automation) |
| Product Category | Infi-Net to Computer Transfer Module (ICT) |
| Host System | Bailey INFI 90 / INFI 90 OPEN / Symphony Harmony DCS |
| Network Interface | INFI-NET (10 Mbaud unidirectional token-passing ring) via INNIS01 |
| Computer Ports | RS-232-C serial (up to 19.2 kbaud) and SCSI parallel (4 Mbytes/sec) via IMMPI01 |
| Point Capacity | Up to 30,000 point definitions (depending on point type) |
| Memory | 512 kbytes ROM + 2 Mbytes RAM on-board |
| Power Supply | +5 VDC from MMU backplane |
| Current Draw | ~2 A / 9.8 W typical |
| Mounting | Single slot in Module Mounting Unit (IEMMU11/12/21/22) with latching faceplate screws |
| Configuration | Onboard DIP-switch matrix for node address; software command-driven |
| Front Panel Indicators | 17 status LEDs + stop/reset pushbutton |
| Host Cable | 60-pin ribbon cable INICT13A P5 → IMMPI01 P6 |
| Termination Units | NTMP01 (RS-232-C, DTE/DCE selectable) or NTCL01 (Cnet coax/twinax) |
| Message Types | Broadcast, time-synchronization, multicast, NIS poll; CRC + checksum protected |
| Operating Environment | Standard Harmony rack, non-corrosive, ESD-sensitive handling required |
| Lifecycle Status | Discontinued / legacy product; serviced through surplus and repair channels |







Reviews