Allen-Bradley 700S-DCP1020Z24​ Safety Control Relay — NEMA 600V, 10 NO / 2 NC, 24V DC Coil

Status: In Stock

Product Overview

The Allen-Bradley 700S-DCP1020Z24​ is a NEMA 600 V safety control relay from Rockwell Automation’s Bulletin 700S family, engineered specifically for use in machine safety circuits where a conventional general-purpose relay is not acceptable. Supplied in a 12-pole configuration with 10 normally open (N.O.) and 2 normally closed (N.C.) contacts and driven by a 24 V DC coil, the Allen-Bradley 700S-DCP1020Z24​ performs the role of a master control relay, safety output coupler or contact expansion device within emergency stop, safety gate, light curtain and interlock architectures. Its defining characteristic is that every pole is mechanically linked in accordance with IEC 60947-5-1 Annex L, which means the N.O. and N.C. contacts are rigidly coupled rather than independent: if a power contact welds, the monitoring contacts are physically prevented from closing, and the safety controller sees the fault instead of assuming a healthy reset.Physically, the Allen-Bradley 700S-DCP1020Z24​ is an open-type device intended for relay rail mounting inside an enclosed control panel, with screw terminals accepting one #18 AWG up to two #12 AWG conductors per point. The recognisable red faceplate carries the IEC mechanically linked symbol, while the tamper-resistant cover permanently fixes the contact blocks so the safety function cannot be modified in the field. There is no push-to-test button and no manual operation, deliberately, because both would create opportunities for a safety function to be bypassed.Within an automation system, the value of the Allen-Bradley 700S-DCP1020Z24​ lies in what it enables downstream. It gives a safety relay or safety PLC trustworthy feedback about the state of the power contacts it is switching, and it delivers the high contact count needed to drop out several contactors, valve banks or drives from a single safety decision. Rated 10 A at 600 V AC and 5 A at 600 V DC with NEMA A600 / P600 make and break capability, and backed by cULus, CE, UL 508 and CSA C22.2 No. 14 approvals, it is a component that lets machine builders design to recognised control-reliability requirements rather than to hope.

Allen-Bradley 700S-DCP1020Z24​ Safety Control Relay — NEMA 600V, 10 NO / 2 NC, 24V DC Coil插图

 

Technical Specifications

Parameter Name Parameter Value
Product Model 700S-DCP1020Z24
Manufacturer Allen-Bradley (Rockwell Automation)
Product Type NEMA 600 V Safety Control Relay, DC Coil (Bulletin 700S)
Contact Configuration 12-pole: 10 N.O. + 2 N.C., all mechanically linked
Rated Control Supply Voltage 24 V DC (coil suffix Z24)
Coil Voltage Range 85–115 % of rated voltage (DC battery charging duty)
Coil Consumption 12.7 W inrush / 12.7 W sealed
Continuous Contact Rating 10 A @ 600 V AC / 5 A @ 600 V DC
Make / Break Ratings NEMA A600 (AC), NEMA P600 (DC)
Minimum Switching Rating 10 V, 50 mA
Contact Material / Design Silver nickel, bifurcated double-break
Operating Time Pick-up 30 ms (DC 30–50 ms), drop-out 20 ms (DC 20–33 ms)
Mechanical Life 10,000,000 operations minimum (12.5 million typical)
Electrical Life 6,000,000 ops at 1 A break, 24 V DC; 1,500,000 ops at 10 A break, 120 V AC
Connection Type / Wire Size Screw terminals; 1 × #18 AWG to 2 × #12 AWG per UL/CSA
Tightening Torque 0.9 – 1.4 N·m (8 – 12 lb-in)
Mounting Open type, relay rail mount (AB relay rail accessory required)
Operating Temperature −20 °C to +65 °C (temperature inside the panel)
Storage Temperature −40 °C to +65 °C
Dimensions / Weight Approx. 84 mm × 55 mm × 142 mm / approx. 0.3 kg
Certifications cULus Listed (File E14840, Guide NKCR/NKCR7), UL 508, CSA C22.2 No. 14, CE, UKCA, EN/IEC 60947-1 & -5-1 Annex L, IEC 337-1, VDE 0660, BS 4794, NEMA ICS-5-2, ANSI B11.19 §5.5.1, EU RoHS
Country of Origin / Lifecycle Mexico / Active (UPC 611320681208)

 

Main Features and Advantages

Mechanically linked contacts that make a welded contact detectable: The core safety principle behind the 700S-DCP1020Z24​ is mechanical linkage across all 12 poles per IEC 60947-5-1 Annex L. In an ordinary relay, N.O. and N.C. contacts move independently, so a welded power contact can close its circuit while the monitoring contact still reports “open” and the safety system believes it is safe. In the 700S-DCP1020Z24, the contacts are rigidly coupled: if an N.O. contact welds, every N.C. contact is held open, and vice versa. A monitoring circuit wired through the N.C. poles therefore detects the fault at the next reset attempt and prevents restart. This is the single feature that separates a safety control relay from a standard machine tool relay, and it is what allows the device to be used in control-reliable circuits.Double-break bifurcated contacts that resist welding in the first place: Detection is the second line of defence; prevention is the first. The 700S-DCP1020Z24​ uses bifurcated double-break contacts that open the circuit in two places, creating two air gaps per pole and reducing the probability of a weld by more than 50 % compared with a single-break design. The bifurcated (split) contact fingers also give two points of contact closure, which improves reliability on the low-energy signals typical of safety feedback loops. Silver nickel contact material provides the arc resistance needed at NEMA A600 / P600 ratings, while the minimum switching capability of 10 V at 50 mA means the same relay can handle both a power contactor coil and a PLC input without contact plating variants.Ten power contacts plus two monitoring contacts in one device: The 10 N.O. / 2 N.C. arrangement of the 700S-DCP1020Z24​ is unusually generous. Ten N.O. poles allow a single safety decision to drop out multiple motor starters, solenoid valve groups, drive enable circuits and indicator circuits simultaneously, removing the need to cascade several relays — and every cascade is another potential failure point. The two N.C. poles are the natural home for the feedback loop that proves the relay has actually dropped out.Design features that protect the integrity of the safety function: The 700S-DCP1020Z24​ is deliberately built to be tamper resistant. Contact blocks are permanently fixed and cannot be added, removed or reconfigured; there is no manual operation or push-to-test button; and the red faceplate with the IEC mechanically linked symbol makes the device instantly identifiable as a safety component during panel inspection or audit. Visual indication of contact state is provided, so a technician can confirm position without instruments. Together with a 24 V DC coil tolerant of 85–115 % supply variation — important on battery-backed DC control supplies that swing during charging — and a 30 ms pick-up / 20 ms drop-out response, the 700S-DCP1020Z24​ delivers predictable behaviour that safety validation calculations can rely on.

Application Field

Emergency stop and safety gate circuits: The most common deployment of the 700S-DCP1020Z24​ is as the output stage downstream of an emergency stop circuit or a safety gate interlock. When an E-stop is pressed or a guard door is opened, the relay drops out its ten N.O. poles to remove power from contactors, solenoid valves and drive enable circuits, while the two N.C. poles report status back to the monitoring device. Because the 700S-DCP1020Z24​ is mechanically linked, a welded pole cannot silently defeat this function.Light curtains, two-hand controls and presence-sensing devices: In presses, packaging machines, assembly cells and robotic workstations, presence-sensing devices initiate a stop but rarely have the contact capacity to interrupt the machine’s power circuits directly. The 700S-DCP1020Z24​ bridges that gap, converting a low-energy safety output into multiple high-capacity isolated switching channels, and providing the monitored feedback that standards such as ANSI B11.19 and ISO 13849 require for control reliability.Master control relay and power-removal functions: Many machine builders use a 700S-DCP1020Z24​ as the master control relay at the top of a panel’s control power distribution. In that role it removes control power to an entire section of a machine in one action, which is both a safety function and a practical maintenance isolation point. The high pole count means one relay can serve several distribution groups without paralleling devices.Process and material handling industries: Beyond discrete machinery, the 700S-DCP1020Z24​ appears in conveyor systems, palletisers, water and wastewater control panels, automotive body shops, food and beverage processing lines and mining equipment — essentially anywhere a 24 V DC control architecture must meet modern machinery safety expectations. Its −20 °C to +65 °C operating range, NEMA 600 V insulation level and DC coil tolerance make it equally suitable for retrofit projects and for new-build panels destined for export, since it carries CE, UKCA, cULus and CSA approvals from a single catalogue number. Panel builders value this because it removes the need to stock region-specific variants of the same safety function.

Allen-Bradley 700S-DCP1020Z24​ Safety Control Relay — NEMA 600V, 10 NO / 2 NC, 24V DC Coil插图1

    Reviews

    There are no reviews yet.

    Be the first to review “Allen-Bradley 700S-DCP1020Z24​ Safety Control Relay — NEMA 600V, 10 NO / 2 NC, 24V DC Coil”
    Review now to get coupon!

    Your email address will not be published. Required fields are marked *

    Back to Top

    Search For Products

    Product has been added to your cart