ABB 1KHL178025R0102P (COM02) Communication Board – Genuine ABB Spare for DCS Controller-to-Field Comms

Status: In Stock

Product Overview

The ABB 1KHL178025R0102P, identified by its functional code COM02, is a communication interface circuit board developed for ABB’s DCS-family backplanes—most prominently the AC31 programmable controller racks and the later Symphony Plus / Melody architecture that carried the AC31 lineage forward into modern 800xA-integrated plants. Unlike a general-purpose serial PCI card or a panel-mounted gateway box, the ABB 1KHL178025R0102P​ is built as a daughter / option card that seats directly onto the DCS controller or the rack backplane, drawing 5 V DC from the backplane bus and consuming under 2 W, so it adds negligible thermal load to the controller slot it occupies. The board’s job is to bridge the controller’s internal bus to the outside world via RS-232 / RS-422 / RS-485 serial ports, carrying Modbus RTU (master or slave), ABB’s native SNP (serial network protocol) and, on firmware-capable variants, Profibus DP-V0 slave—making it the serial “exit door” for an AC31 or Symphony Plus node that needs to talk to HMIs, SCADA, third-party PLC drops, or legacy field devices without consuming a full rack position for an external gateway.Physically the 1KHL178025R0102P​ (COM02) is a compact PCB in the region of 100 × 150 mm (some revisions ~152 × 105 mm) with a lightweight ~0.15–0.22 kg footprint, populated with a 9-pin D-sub for the serial port and screw-terminal blocks for RS-485/422 shield-and-pair landing, and rated for 1.5 kV channel-to-bus isolation so that a field-side surge on a long RS-485 run does not propagate into the DCS backplane. Standard operating temperature is quoted at 0 °C to +60 °C for the base industrial build, with wider-temperature revisions pushed to -40 °C to +85 °C for harsh-cabinet deployments; the PCB substrate follows ABB’s industrial FR-4 coating discipline consistent with DCS spare expectations. Because the ABB 1KHL178025R0102P​ is a model-specific DCS spare rather than a configurable universal serial card, the DIP-switch block and EEPROM handshake are pre-aligned to the AC31 / Symphony backplane timing, which means a like-for-like swap normally requires nothing more than matching the DIP settings from the removed board—no firmware download, no rack re-configuration, no re-marshalling of the serial cable (the D-sub and terminals land the same either side). For plants still running AC31-based process sections underneath a modern 800xA overlay—common in power-gen, pulp & paper, and metals—the COM02 remains the targeted spare that keeps the legacy rack talking to the modern layer without a cabinet retrofit.

ABB 1KHL178025R0102P (COM02) Communication Board – Genuine ABB Spare for DCS Controller-to-Field Comms插图

 

Technical Specifications

Parameter Name Parameter Value
Product Model 1KHL178025R0102P
Manufacturer ABB
Product Type Communication Interface Circuit Board (COM02)
Platform Fit ABB AC31 / Symphony Plus (Melody) DCS racks; 800xA-integrated legacy nodes
Supply Voltage 5 V DC via DCS backplane (typical); some revisions accept external 24 V DC for field-side power
Power Dissipation < 2 W
Serial Interfaces RS-232 / RS-422 / RS-485 (port count and pinout revision-dependent)
Supported Protocols Modbus RTU / ASCII (master or slave), ABB SNP, Profibus DP-V0 slave (fw variant)
Baud Rate Range 300 bps to 115.2 kbps
Isolation 1.5 kV channel-to-backplane (field side to system side)
Connectors 9-pin D-sub (serial port), screw terminals (RS-485/422 shield + pair)
Operating Temperature 0 °C to +60 °C (base); -40 °C to +85 °C (wide-temp revision)
Storage Temperature -40 °C to +85 °C
Dimensions (L × W) ~100 × 150 mm (some builds ~152 × 105 mm)
Weight ~0.15–0.22 kg
Mounting DCS rack backplane / daughter-card slot (panel or rail adapter per cabinet)

 

Main Features and Advantages

Multi-protocol serial posture: The core reason plants keep the ABB 1KHL178025R0102P​ on the spare list is that one small card covers three distinct serial dialects. Modbus RTU master/slave handles the vast universe of third-party drives, flow computers, and power meters that expect a 2-wire RS-485 conversation. ABB SNP is the native serial network protocol that older AC31 drops and Symphony Plus I/O stations use among themselves, so the COM02 can also serve as the link that pulls a remote AC31 satellite rack’s I/O into the main controller’s scan. Profibus DP-V0 slave on firmware-capable revisions adds a third lane—less common on this card than on ABB’s CI-series Profibus masters, but useful when the COM02 needs to present itself as a Profibus slave to a higher-tier DCS or PLC. For a cabinet that still runs an AC31 CPU but needs to speak to both a modern SCADA (Modbus) and a legacy satellite rack (SNP), the 1KHL178025R0102P​ collapses what would otherwise be two gateway boxes into one slot.Backplane-powered, not PSU-hungry: Drawing < 2 W from the 5 V backplane, the ABB 1KHL178025R0102P​ does not need a dedicated 24 V feed, does not need a DIN-rail PSU, and does not add heat to a cabinet that may already be pushing its fan budget. In 5-slot AC31 racks where the power budget per slot is accounted, this matters—the COM02 slides in without nudging the rack’s power headroom calculation.Isolation that actually protects the rack: 1.5 kV channel-to-backplane isolation is the headline number, but the practical value is this—when an RS-485 run to a remote tank-farm flow computer takes a lightning-induced surge or a 50 V common-mode offset from a ground-looped shield, the 1KHL178025R0102P​ absorbs it on the field side and the AC31 backplane (and the rest of the DCS rack) stays alive. Plants that have learned this the hard way tend to keep one spare COM02 per rack precisely because the alternative is a backplane-voltage spike taking out the CPU next door.DIP + EEPROM discipline: Configuration on the ABB 1KHL178025R0102P​ is handled through a DIP switch block (baud, parity, echo on/off, node address range) plus an EEPROM that stores the module identity for the rack bus scan. The most common “ghost fault” on this card is echo left ON for half-duplex RS-485—TX collides with RX and the Modbus master sees garbled frames. Switch 3 OFF disables echo; it is a five-second fix once you know it, and the COM02’s DIP accessibility makes that possible without pulling the rack offline for firmware work. Because the 1KHL178025R0102P​ is detected by the rack at bus scan, a mismatched EEPROM shows up immediately as “module not recognized” rather than as a silent data corruption—again, faster root-cause than an external gateway would give you.Revision-awareness and 1KHL numbering: Like other ABB 1KHL-prefixed spares, the ABB 1KHL178025R0102P​ has seen component-spin updates across its production life. The R0102P suffix anchors the revision; swapping to a different R-suffix without checking DIP and EEPROM compatibility can produce a rack-detect mismatch on older AC31 firmware. Best practice—photograph the DIP block and the removed board’s label before ordering, and ask the supplier to cross-check the R-suffix against your rack’s AC31 CPU firmware level. It is a ten-minute email that prevents a “fits mechanically, rejected by bus scan” return.

 