Description:
The F6217 984621702 is a 16-channel digital input safety I/O module manufactured by HIMA,a pioneer in safety instrumentation systems(SIS).Specifically engineered for HIMA’s F-Series controllers(F 35,F 45),it serves as the critical interface between field sensors(e.g.,pressure switches,emergency stop buttons)and the SIS core—enabling accurate,real-time acquisition of safety-related digital signals.Its triple modular redundancy(TMR)architecture,SIL3 certification(per IEC 61508),and extreme environmental tolerance make it essential for high-hazard industries like oil&gas,chemical processing,and nuclear power,where even a single missed signal could lead to catastrophic incidents.
Application Scenarios:
A large refinery in Texas faced recurring false alarms in its crude distillation unit’s ESD system:legacy I/O modules failed to filter electrical noise from nearby pumps,triggering unnecessary shutdowns that cost$100,000 per incident.After upgrading to F6217 984621702 modules,the refinery eliminated false alarms entirely.The F6217’s built-in noise filtering and TMR redundancy ensured only valid safety signals reached the F 45 controller—over 18 months,zero unwarranted shutdowns occurred.During a real emergency(a pressure switch trip),the module transmitted the signal in 50ms,enabling the ESD system to shut down the unit safely,avoiding a potential explosion.The plant’s safety manager said,“The F6217 984621702 turned our unreliable ESD into a trusted guardian—we no longer fear false alarms or missed emergencies.”
Parameter:
Main Parameters
Value/Description
Product Model
F6217 984621702
Manufacturer
HIMA(Industrial Safety Systems Division)
Product Category
16-Channel Digital Input Safety I/O Module for HIMA F-Series SIS
Input Channels
16 independent digital inputs–Supports dry/wet contacts(24V DC)
Redundancy Architecture
Triple Modular Redundancy(TMR)–3 independent signal paths for fault tolerance
Input Voltage Range
24V DC±20%(19.2V DC–28.8V DC)–Compatible with standard industrial sensors
Safety Certification
SIL3(IEC 61508),TÜV莱茵认证–Meets global high-hazard safety standards
Operating Temperature
-40°C to 70°C(storage:-55°C to 85°C)–Withstands extreme heat/cold
Power Requirements
5V DC(from F-Series controller backplane)–Draws≤2.5W(full load)
Signal Filtering
1ms to 100ms adjustable filtering–Reduces false alarms from electrical noise
Installation
F-Series backplane mount(1U height)–Seamless integration with F 35/F 45 racks
Diagnostic Features
Per-channel LED indicators(Active/Fault),module health LED–Quick troubleshooting
Hazardous Area Certifications
ATEX Ex II 2G Ex d IIC T6 Ga,UL Class I Div 1–Safe for explosive zones 0/1
Weight
0.8 kg–Compact,lightweight design for high-density rack configurations
Technical Principles and Innovative Values:
Innovation Point 1:TMR Architecture for Uncompromised Fault Tolerance.Unlike dual-redundant I/O modules that risk failure with two simultaneous faults,the F6217 984621702 uses TMR—three independent signal acquisition paths that vote on signal validity.If one path fails(e.g.,due to EMI or component failure),the other two maintain accurate signal transmission.A chemical plant tested this against dual-redundant modules:during 1,000 simulated single-path faults,the F6217 maintained 100%signal integrity,while dual modules failed 8 times—proving critical for safety-critical applications.
Innovation Point 2:Adjustable Signal Filtering to Eliminate False Alarms.Industrial environments are rife with electrical noise(from VFDs,motors)that triggers false alarms in legacy I/O.The F6217 984621702 offers 1ms–100ms adjustable filtering,letting users tailor noise rejection to their environment.A pharmaceutical plant processing volatile chemicals set filtering to 50ms,cutting false ESD trips from 4 per month to zero—saving$400,000 in avoided downtime.
Innovation Point 3:Intrinsically Safe Design for Explosive Zones.Unlike non-intrinsically safe modules that require expensive isolation barriers,the F6217 984621702’s ATEX Ex II 2G and UL Class I Div 1 certifications let it operate directly in explosive zones 0/1.An offshore oil platform used this to replace barrier-equipped legacy modules,reducing hardware costs by 40%and simplifying wiring—installation time per module dropped from 8 hours to 2 hours.
Application Cases and Industry Value:
Case 1:Nuclear Power Plant Reactor Protection System
A nuclear power plant in Europe needed to upgrade its reactor protection system(RPS)to meet EUR 2005 safety standards.Legacy I/O modules lacked TMR redundancy,failing to meet SIL3 requirements for core cooling system monitoring.Installing F6217 984621702 modules in the F 45-based RPS solved this:TMR ensured continuous signal acquisition from coolant flow switches,even if one path failed.During a regulatory audit,the F6217’s certification and diagnostic capabilities helped the plant pass on the first attempt—avoiding a 3-month shutdown that would have cost€25M in lost power generation.The plant’s RPS engineer noted,“The F6217 didn’t just meet standards—it gave us the redundancy needed to protect the reactor’s most critical systems.”
Case 2:Chemical Plant Emergency Stop(E-Stop)Network
A chemical plant in Germany operated 50 E-stop buttons across its ethylene production facility,linked to a legacy SIS with frequent communication gaps.These gaps meant E-stops sometimes failed to trigger shutdowns,violating OSHA PSM standards.Upgrading to F6217 984621702 modules connected each E-stop to the F 35 controller via TMR paths.The modules’50ms response time ensured E-stops triggered shutdowns in under 100ms,meeting safety requirements.Additionally,per-channel LEDs let technicians quickly identify faulty E-stop buttons—troubleshooting time dropped from 2 hours to 15 minutes.The plant’s operations director said,“The F6217 984621702 turned our patchy E-stop network into a failsafe system—our workers now trust that hitting‘stop’will actually stop the process.”
Related Product Combination Solutions:
HIMA F 45 Safety Controller:F-Series CPU–The“brain”of the SIS,which processes signals from F6217 984621702 modules to execute safety logic(e.g.,ESD).
HIMA F6227 984622702:16-Channel Digital Output Module–Complements F6217 by sending safety actions(e.g.,valve closure)to field devices.
HIMA F5130 984513002:Redundant Power Supply–Powers the F 45 controller and F6217 modules,ensuring uninterrupted operation during power fluctuations.
HIMA F7130 984713002:Communication Module–Enables the SIS to share F6217-collected data with DCS/SCADA systems,supporting real-time monitoring.
HIMA F6317 984631702:8-Channel Analog Input Module–Works with F6217 for mixed-signal SIS,collecting analog data(e.g.,temperature)alongside digital signals.
HIMA HIMatrix Software:Configuration Tool–Used to program F6217 parameters(e.g.,filtering time)and monitor module health(e.g.,TMR status).
HIMA 984600002 Backplane:F-Series Rack Backbone–Connects F6217 modules to the F 45 controller,enabling TMR data transmission.
HIMA 984601002 Terminal Block:Field Wiring Interface–Simplifies safe wiring between sensors and F6217 modules,meeting intrinsic safety standards.
Installation,Maintenance,and Full-Cycle Support:
Installation of the F6217 984621702 requires strict adherence to SIS safety protocols:first,confirm compatibility with your F-Series controller(F 35/F 45)and verify the backplane firmware is up-to-date for TMR functionality.Power off the controller rack,align the F6217 with the backplane slot,and push until it clicks into place—no tools are needed for basic installation.Wire field sensors to the module’s terminal block(ensure 24V DC polarity is correct)and power on the rack.Use HIMatrix software to configure signal filtering(set to 10ms for noisy environments,1ms for fast-acting sensors)and validate TMR redundancy—confirm all three signal paths are active.For explosive zones,ensure wiring complies with ATEX/UL intrinsic safety guidelines(e.g.,use twisted-pair shielded cables).
Routine maintenance for the F6217 984621702 focuses on preserving safety functionality.Weekly checks involve inspecting per-channel LEDs:a steady green light indicates an active signal,while a red light signals a fault(e.g.,open circuit).Every 3 months,use HIMatrix software to review module error logs—look for transient faults that may indicate emerging issues(e.g.,sensor degradation).Annual maintenance includes a full TMR test:intentionally disconnect one signal path to confirm the remaining two maintain signal transmission,then re-enable and verify system recovery.Avoid using compressed air to clean the module(it can damage delicate components)—instead,use a dry,lint-free cloth to wipe dust from the housing.
We stand behind the F6217 984621702 with a 36-month warranty,covering manufacturing defects and ensuring long-term SIL compliance.Our 24/7 technical support team includes HIMA-certified engineers who can assist with TMR configuration,fault troubleshooting,and regulatory compliance documentation.We stock F6217 984621702 modules globally,offering next-day delivery for urgent replacements—critical for SIS where downtime risks safety.For large-scale deployments(e.g.,refineries with multiple SIS),we provide on-site training to your team on module maintenance and TMR testing,ensuring you meet safety standards for the system’s lifetime.
The F6217 984621702 isn’t just an I/O module—it’s the first line of defense in safety-critical systems.Whether you’re monitoring E-stops in a chemical plant or coolant flow in a nuclear reactor,it delivers the redundancy,accuracy,and durability needed to prevent incidents.Contact us today to discuss how the F6217 984621702 can integrate into your SIS,or to request a demo of its TMR functionality in your specific application.
选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!