Description
The GE 517-0224-16A-458525 is a custom-engineered terminal assembly manufactured by General Electric for integration into industrial turbine and excitation control panels,particularly within legacy Mark V and EX2000 systems.This module is not a standard catalog item but a project-specific,pre-wired terminal block configuration designed to streamline field wiring,enhance maintainability,and ensure consistent power distribution to critical auxiliary devices.
Typically mounted on DIN rails inside control cabinets,the GE 517-0224-16A-458525 integrates fused circuits,labeling,and standardized screw terminals to serve as a reliable interface between controller outputs(e.g.,from RTBA or DTBA boards)and field equipment such as solenoids,relays,sensors,and motor starters.
Application Scenarios
At a natural gas-fired power station in Texas,engineers faced recurring nuisance trips due to intermittent 24VDC supply faults to fuel valve solenoids.Investigation traced the issue to corroded,unlabeled terminal blocks installed during a 1990s retrofit—blocks that lacked fuse protection and clear identification.The plant replaced the obsolete assembly with a genuine GE 517-0224-16A-458525,which matched the original Mark V panel documentation exactly.The new unit featured color-coded,fused circuits with engraved labels and conformal coating.Within six months,solenoid-related faults dropped to zero,and maintenance time during outages was reduced by 40%.The GE 517-0224-16A-458525 proved essential not just as a wiring component—but as a safeguard for operational continuity and regulatory compliance.
Parameter
Main Parameters Value/Description
Product Model 517-0224-16A-458525
Manufacturer General Electric(GE Power/GE Vernova)
Product Category Custom Terminal Assembly/Fused Terminal Block Module
Configuration 16-position screw-terminal block with integrated fuse holders(2–4 fused circuits typical)
Voltage Rating 250V AC/30V DC(per terminal)
Current Rating 16A continuous per circuit(as indicated by“16A”in model)
Fuse Type 5x20mm or blade-type fuses(field-replaceable,typically 2A–10A based on application)
Mounting DIN rail(35mm standard),panel-mount optional
Labeling Laser-engraved or printed circuit identifiers(e.g.,“SOLV_FUEL_TRIP”,“24V_AUX”)
Protection Conformal coated(IPC-CC-830 compliant)for humidity,dust,and chemical resistance
Standards Compliance UL 508,CE,RoHS
Typical Use Case Interface between Mark V/EX2000 output modules and field actuators/sensors
Technical Principles and Innovative Values
Innovation Point 1:Application-Specific Engineering
Unlike generic terminal blocks,the GE 517-0224-16A-458525 is engineered for a specific turbine or excitation system configuration—ensuring pinout accuracy,fuse coordination,and labeling consistency with original GE schematics.
Innovation Point 2:Integrated Fault Containment
Each critical circuit includes dedicated fuse protection,preventing a single shorted solenoid or sensor from disabling an entire I/O group—a key reliability feature in safety-critical turbine shutdown logic.
Innovation Point 3:Maintenance-First Design
Clear,permanent labeling and accessible fuse access allow technicians to diagnose and replace components in minutes without consulting wiring diagrams—critical during forced outages.
Innovation Point 4:Environmental Hardening
Conformal coating protects copper traces and fuse contacts from salt air,hydrogen atmospheres(in generator enclosures),and high-humidity environments common in coastal or combined-cycle plants.
Application Cases and Industry Value
A hydroelectric facility in Canada upgraded its aging Westinghouse-excited generator controls using a hybrid Mark V interface panel.During commissioning,inconsistent trip signals plagued the system due to voltage drops across non-fused terminal strips.Engineers sourced an exact-match GE 517-0224-16A-458525 based on the original P&ID tag.The assembly restored clean 24VDC delivery to all trip relays,passed IEEE C37.90 dielectric testing,and enabled seamless integration with the existing DSP-based logic.The utility reported a 90%reduction in false alarms over two years and credited the GE 517-0224-16A-458525 as a“silent guardian”of grid reliability.
In another case,a refinery in Singapore used the GE 517-0224-16A-458525 to standardize spare parts across three Mark V-controlled steam turbines.By replacing mismatched third-party terminals with genuine GE assemblies,they cut inventory SKUs by 60%and eliminated wiring errors during emergency repairs.
Related Product Combination Solutions
GE DS200RTBAG2AFB:Relay output board whose dry contacts often feed into the GE 517-0224-16A-458525 for solenoid actuation
GE DS200DTBAG2A:Digital output driver that supplies 24VDC signals routed through the terminal assembly
GE DS200PCCAG1ABB:Power Connect Card that may source the 24VDC rail protected by fuses in the GE 517-0224-16A-458525
Phoenix Contact UK5-TWIN:Common industrial terminal block sometimes used as a mechanical reference
GE IS200TRGLH1A:Trip manifold interface often wired via this terminal assembly in Mark V systems
Littelfuse 272 Series:Standard fuse type compatible with the fuse holders in the GE 517-0224-16A-458525
GE Manual GEH-6190:Mark V Hardware Reference—contains terminal schedules matching this assembly
Weidmüller SAKE 6/EN:Alternative terminal block platform occasionally substituted in retrofits
Installation,Maintenance,and Full-Cycle Support
Installing the GE 517-0224-16A-458525 requires no programming—only mechanical mounting and wire termination.Technicians should verify fuse ratings against the original system documentation and torque terminals to 0.6 Nm to prevent loosening under vibration.The assembly’s DIN-rail design allows rapid replacement during outages,often in under 15 minutes when used as a direct swap.
For maintenance,annual inspections should include checking for fuse discoloration,terminal corrosion,and label legibility.In high-humidity sites,infrared scans can detect resistive heating at loose connections.Because the GE 517-0224-16A-458525 mirrors GE’s original engineering,it integrates seamlessly into predictive maintenance programs and supports compliance with NERC PRC-005 and ISO 55000 asset management standards.
Every GE 517-0224-16A-458525 we supply is reverse-engineered from verified field units or OEM drawings,tested for continuity and insulation resistance,and shipped with a terminal map and fuse schedule.Our team provides remote support to validate compatibility with your specific turbine serial number and control revision.With decades of experience supporting legacy GE infrastructure,we ensure your terminal-level reliability matches your process-critical demands.
Contact us for a customized solution—whether you need one GE 517-0224-16A-458525 for emergency repair or a full panel upgrade kit for fleet standardization.Keep your Mark V,EX2000,or hybrid system running with precision-engineered interfaces built to GE’s original vision.