Product Overview
The HIMA LM002_MAX 985020002 is a high-performance local monitoring and diagnostics module designed for integration into HIMA’s HIMax safety instrumented systems(SIS).As part of the HIMax X series architecture,the HIMA LM002_MAX 985020002 serves as a dedicated interface for real-time status visualization,local operator interaction,and system health monitoring directly at the safety controller cabinet.This module enhances operational transparency without compromising the integrity of the certified safety functions,making it ideal for environments where immediate access to system diagnostics is critical—such as oil&gas processing,chemical plants,and power generation facilities.
Unlike standard I/O modules,the HIMA LM002_MAX 985020002 does not participate in safety logic execution but instead acts as a secure window into the HIMax system’s operational state.It provides LED-based indication of module status,communication health,and fault conditions,while also supporting optional local acknowledgment of alarms or test initiation via integrated pushbuttons.The HIMA LM002_MAX 985020002 is fully compliant with IEC 61508 and IEC 61511 standards up to SIL 3,ensuring that its presence in the safety loop does not degrade overall system reliability.Its robust design,electromagnetic resilience,and seamless integration with HIMA Engineering Studio make it a trusted component in global safety-critical infrastructures.
Technical Specifications
Parameter Name Parameter Value
Product Model LM002_MAX 985020002
Manufacturer HIMA Paul Hildebrandt GmbH+Co KG
Product Type Local Monitoring and Diagnostics Module for HIMax SIS
Module Width 20 mm(standard HIMax rail unit)
Power Supply Supplied via HIMax backplane(no external wiring required)
Operating Voltage+5 V DC(from system backplane)
Indicators Multiple status LEDs(RUN,ERROR,COM,OK),channel-specific fault LEDs
Local Interface Integrated pushbuttons for alarm acknowledge/test(configurable)
Communication Internal HIMax bus(no external protocol;communicates with CPU via backplane)
Operating Temperature 0°C to+60°C
Installation Method DIN rail mounting within HIMax chassis
Certifications IEC 61508 SIL 3,IEC 61511,ATEX(optional for hazardous areas),CE,UL
Main Features and Advantages
Enhanced On-Site Diagnostics:The HIMA LM002_MAX 985020002 provides immediate visual feedback on module and system status through a comprehensive array of color-coded LEDs.Operators can instantly identify communication failures,internal faults,or channel-specific errors without connecting a laptop or accessing engineering software—reducing mean time to repair(MTTR)during critical incidents.
Secure Local Interaction:Equipped with tamper-resistant pushbuttons,the HIMA LM002_MAX 985020002 allows authorized personnel to locally acknowledge alarms,initiate partial stroke tests,or confirm maintenance modes—actions that are logged and synchronized with the central safety logic.These functions are configurable via HIMA Engineering Studio and subject to user role permissions,ensuring no unauthorized override of safety functions.
Zero Impact on Safety Integrity:As a non-voting,non-logic module,the HIMA LM002_MAX 985020002 operates entirely outside the safety-critical data path.It draws power and data from the HIMax backplane but does not influence the execution of safety instrumented functions(SIFs).This architectural separation guarantees that diagnostic convenience never compromises functional safety certification.
Compact and Maintenance-Friendly:With a standard 20 mm width,the HIMA LM002_MAX 985020002 fits seamlessly into existing HIMax racks without requiring chassis redesign.Its hot-swap capability(in supported configurations)enables replacement during operation,minimizing downtime.All diagnostics are mirrored in HIMA’s Safety Suite software,enabling both local and remote troubleshooting.
Application Field
The HIMA LM002_MAX 985020002 is widely deployed in process industries where rapid on-site diagnosis of safety system status is essential for operational continuity and regulatory compliance.In offshore oil&gas platforms,for example,technicians use the module’s LED indicators to verify the health of emergency shutdown(ESD)subsystems during routine rounds—ensuring readiness without disrupting live processes.Similarly,in chemical manufacturing plants handling toxic or reactive materials,the HIMA LM002_MAX 985020002 enables safe local acknowledgment of nuisance alarms during maintenance windows,reducing unnecessary plant trips.
In power generation,particularly in combined-cycle or biomass facilities,the HIMA LM002_MAX 985020002 supports boiler protection and turbine overspeed systems by providing clear visual confirmation of I/O module status during startup sequences.It is also used in water treatment and pipeline compression stations where remote or unmanned operation demands reliable local feedback in case of communication loss to central control rooms.Because it requires no external wiring or configuration beyond initial setup,the HIMA LM002_MAX 985020002 is especially valuable in brownfield retrofits where adding new cabling is cost-prohibitive or physically constrained.
Related Products
F7132:HIMax CPU module—core processing unit that the LM002_MAX 985020002 monitors
F7161:Digital input module for 24 V DC signals—often installed in same rack as LM002_MAX 985020002
F7171:Digital output module with relay contacts—paired with monitoring for output verification
F7221:Analog input module for 4–20 mA—status visible via LM002_MAX 985020002 diagnostics
H41q:Compact HIMax variant—uses different local monitor(not compatible with LM002_MAX 985020002)
ESD-MON:Third-party mimic panel—external alternative,less integrated than LM002_MAX 985020002
HIMA PES:Legacy programmable electronic system—predecessor platform without this module type
Installation and Maintenance
Pre-installation preparation:Before installing the HIMA LM002_MAX 985020002,confirm compatibility with the HIMax chassis firmware version and ensure the target slot is powered down if hot-swap is not enabled.Verify that the backplane connector is clean and undamaged,and align the module carefully to avoid bending pins during insertion.Although no external wiring is needed,ensure adjacent modules are securely seated to maintain proper backplane contact across the entire rack.
Maintenance recommendations:Regularly inspect the LEDs on the HIMA LM002_MAX 985020002 during site walkthroughs to detect early signs of communication degradation or internal faults.If a fault LED illuminates,cross-reference the condition with HIMA Safety Suite logs before initiating replacement.When servicing,always follow lockout/tagout procedures—even though the module carries no field wiring,it resides in an energized safety controller chassis.Store spare HIMA LM002_MAX 985020002 units in ESD-safe packaging at ambient temperature to preserve long-term reliability.
Product Guarantee
Every HIMA LM002_MAX 985020002 we supply is sourced from authorized channels or verified surplus inventory and undergoes full functional testing,including LED illumination verification,button response validation,and backplane communication check.We guarantee authenticity,compliance with original HIMA specifications,and full traceability via serial number.Backed by a 12-month warranty,each HIMA LM002_MAX 985020002 comes with technical documentation and expert support for integration into existing HIMax systems.In safety-critical operations,visibility equals control—and we ensure your local monitoring is as reliable as your safety logic.
选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!