Description
The Honeywell XNX-UTAV-RNIF1 is a configurable, multi-sensor universal gas detection transmitter designed for industrial safety applications. It serves as the central processing unit for a wide range of toxic, combustible, and oxygen gas sensors (including catalytic bead, infrared (IR), electrochemical, and PID types). The “RNIF1” suffix denotes integration with a Remote Network Interface Module, enabling direct communication over digital field networks—most commonly Modbus RTU over RS-485—for seamless integration into DCS, PLC, or safety systems.
Engineered for hazardous environments and certified to global standards, the XNX-UTAV-RNIF1 delivers real-time gas concentration data, diagnostic status, and alarm events while supporting remote configuration and calibration—reducing maintenance time and improving personnel safety.
Application Scenarios
At a Gulf Coast chemical terminal, legacy fixed gas detectors required technicians to enter confined spaces monthly for bump testing—posing significant safety and compliance risks. After deploying the XNX-UTAV-RNIF1 with infrared methane and electrochemical H₂S sensors, all units were networked via Modbus RTU to a central Honeywell Experion® PKS system. Operators now perform remote validation, receive predictive sensor health alerts, and view live gas maps from the control room. In its first year, the site eliminated 200+ high-risk entries and cut calibration labor by 60%. For this team, the XNX-UTAV-RNIF1 transformed gas detection from a compliance burden into an intelligent safety layer.
Parameter
表格
Technical Principles and Innovative Values
Innovation Point 1: True Universal Platform – One Transmitter, Any Gas
The XNX-UTAV-RNIF1 auto-detects and configures for over 30 sensor types via plug-and-play cartridges—eliminating the need for multiple transmitter models in inventory.
Innovation Point 2: Digital Integration Without Gateways
The integrated RNIF1 module outputs native Modbus RTU, allowing direct connection to PLCs (e.g., Allen-Bradley, Siemens) or DCS (e.g., Honeywell Experion, Emerson DeltaV)—no third-party protocol converters needed.
Innovation Point 3: Remote Lifecycle Management
Using Modbus registers, operators can read gas values, acknowledge alarms, initiate self-tests, and even trigger remote calibrations—minimizing exposure in toxic or explosive zones.
Innovation Point 4: Safety-Certified Intelligence
With built-in diagnostics and SIL 2 compliance, the XNX-UTAV-RNIF1 supports functional safety loops (e.g., triggering ventilation or shutdown) while providing asset health data for predictive maintenance.