🔍Product Overview
The ALTOM UT150-1 is a universal 2-wire temperature transmitter designed for industrial process control and monitoring applications.It converts signals from various temperature sensors—such as RTDs(Pt100,Pt1000,Ni100)and thermocouples(Type J,K,T,E,etc.)—into a standardized 4–20 mA analog output signal,which can be transmitted over long distances with minimal signal loss.
This loop-powered transmitter is widely used in industries including oil&gas,chemical processing,HVAC,water/wastewater,power generation,and manufacturing,where accurate and reliable temperature measurement is critical.
The UT150-1 features universal input compatibility,meaning it can be configured for multiple sensor types and temperature ranges,making it a flexible and cost-effective solution for diverse applications.
📋Technical Specifications
Parameter Specification
Model ALTOM UT150-1
Type 2-Wire Loop-Powered Temperature Transmitter
Input Sensor Types RTD:Pt100,Pt1000,Ni100<br>Thermocouple:J,K,T,E,N,R,S,B,L,U
Input Range Configurable(based on sensor type and span)
Output Signal 4–20 mA DC(2-wire)
Loop Supply Voltage 12–35 V DC(minimum 12 V at 20 mA)
Output Load Up to 600Ω 24 V DC
Accuracy±0.1%of span(typical),±0.3%max(including sensor)
Cold Junction Compensation(CJC)Built-in(for thermocouples)
Temperature Drift<0.01%of span/°C
Response Time<500 ms(programmable damping)
Power Consumption<2 W(loop-powered)
Connection Screw terminals(sensor in,output out)
Housing Material High-impact plastic(IP65 rated)
Mounting DIN rail(TS35)or panel mount
Operating Temperature-20°C to+70°C(-4°F to 158°F)
Storage Temperature-40°C to+85°C
Protection Reverse polarity,overvoltage,short-circuit
Approvals CE,RoHS compliant
✅Key Features&Advantages
Universal Input:Accepts RTDs and thermocouples,reducing inventory needs and increasing application flexibility.
Loop-Powered(2-Wire):No separate power supply required—powered by the 4–20 mA loop,simplifying wiring and installation.
High Accuracy&Stability:Ensures precise temperature measurement for process control and safety systems.
DIN Rail Mounting:Easy integration into control panels and switchgear.
Isolated Design:Provides galvanic isolation between input and output(optional models),reducing noise and ground loop issues.
Configurable via Software or DIP Switches:Some variants allow range and sensor type selection via DIP switches or PC configuration tools.
Wide Operating Range:Suitable for harsh industrial environments.
Cost-Effective:Replaces multiple single-type transmitters with one universal device.
🏭Typical Applications
Process Temperature Monitoring:In reactors,boilers,heat exchangers,and pipelines.
HVAC Systems:Chilled water,steam,and air temperature control.
Machinery Protection:Bearing,motor,and gearbox temperature monitoring.
Water&Wastewater Treatment:Tank and effluent temperature measurement.
Power Plants:Generator,transformer,and turbine temperature monitoring.
Food&Beverage:Cooking,fermentation,and storage temperature control.
OEM Equipment:Integrated into original equipment for temperature feedback.
🔗Related Products&Accessories
Product Description
ALTOM UT150-2 3-wire or 4-wire version with higher isolation
ALTOM UT150-EX Intrinsically safe version for hazardous areas
ALTOM UT200 Series Smart temperature transmitters with HART communication
RTD Sensors Pt100,Pt1000 probes compatible with UT150-1
Thermocouple Probes Type K,J,T sensors for high-temp applications
DIN Rail Terminal Blocks For signal wiring and distribution
4–20 mA Isolators For signal splitting or noise suppression
⚙️Installation Guide
Mounting:Clip the UT150-1 onto a 35 mm DIN rail in the control panel.
Sensor Connection:Wire the temperature sensor(RTD or TC)to the input terminals(observe polarity for TC).
Output Wiring:Connect the 4–20 mA output in series with the loop power supply(12–35 V DC)and receiving device(PLC,DCS,controller).
Configuration:Set sensor type and range using DIP switches(if available)or software(if supported).
Power Up:Apply voltage and verify output with a multimeter or HART communicator.
Calibration Check:Test with known temperature source if required.
⚠️Note:Ensure correct sensor type selection to avoid measurement errors.
🛠️Maintenance Tips
Periodically check for loose wiring or corrosion.
Verify output signal during routine calibration.
Replace if output drifts beyond acceptable limits.
Use protective conduit in high-vibration or wet environments.
🛡️Product Guarantee
Every ALTOM UT150-1 is tested for input accuracy,output stability,and insulation integrity.We offer a 12-month warranty covering defects in materials and workmanship.Designed for long-term reliability,the UT150-1 delivers consistent performance in demanding industrial environments.
💡Summary
The ALTOM UT150-1 is a versatile,loop-powered temperature transmitter that bridges the gap between field temperature sensors and control systems.Its universal input capability,DIN rail design,and 4–20 mA output make it an ideal choice for engineers and technicians seeking a reliable,easy-to-install solution for temperature signal conditioning in industrial automation.