Allen-Bradley 1734-ADN POINT I/O DeviceNet Adapter Module 24VDC缩略图

Allen-Bradley 1734-ADN POINT I/O DeviceNet Adapter Module 24VDC

Allen-Bradley 1734-ADN POINT I/O DeviceNet Adapter Module 24VDC插图

 

Product Overview

The ALLEN-BRADLEY 1734-ADN is a POINT I/O DeviceNet Network Adapter engineered to serve as the communication gateway between POINT I/O modules and a DeviceNet network. As a core component of the Bulletin 1734 POINT I/O distributed I/O system, the ALLEN-BRADLEY 1734-ADN operates simultaneously on the primary DeviceNet network and the internal POINTBus backplane, functioning as both a DeviceNet slave to the network master and a master scanner for the POINT I/O modules on its backplane . This dual-network role enables the adapter to collect I/O data from connected modules and transmit it to a DeviceNet scanner (such as the 1756-DNB), while also receiving output commands from the controller and routing them to the appropriate I/O modules.

The ALLEN-BRADLEY 1734-ADN supports up to 63 POINT I/O modules on its backplane, accommodating a maximum of 504 I/O points . The adapter features autobaud capability, automatically detecting and matching the DeviceNet network baud rate from 125K, 250K, or 500K bits per second . Its auto-start mode, available in Series B versions, automatically configures all backplane modules by reading module IDs, setting sequential addresses, and generating a scan list—reducing commissioning time from hours to seconds . The ALLEN-BRADLEY 1734-ADN also supports Auto Device Replacement (ADR), allowing failed modules to be replaced without manual reconfiguration, as the adapter transfers stored configuration parameters to the new module automatically .

The module operates from a 24V DC power supply, provides 1000 mA of POINTBus current for backplane modules, and features LED indicators for adapter status, DeviceNet status, and POINTBus status . The ALLEN-BRADLEY 1734-ADN is designed for DIN rail mounting and supports Removal and Insertion Under Power (RIUP), enabling module replacement without system shutdown . As of December 31, 2026, this adapter has been discontinued by Rockwell Automation with no planned direct replacement, making existing inventory increasingly valuable for maintenance of installed systems .

 

Technical Specifications

Parameter Name Parameter Value
Product Model 1734-ADN
Manufacturer Allen-Bradley (Rockwell Automation)
Product Type POINT I/O DeviceNet Network Adapter
Series POINT I/O 1734
Input Voltage 24V DC
Field Side Power 400 mA
Inrush Current 6 A
POINTBus Current 1000 mA
Power Consumption 8.1 W
Maximum Modules 63 POINT I/O modules
Maximum I/O Points 504
DeviceNet Baud Rates 125K, 250K, 500K bits/second
Dimensions (H×W×L) 76.2 × 54.9 × 133.4 mm
Weight 0.34 kg
Operating Temperature -20°C to +55°C
Mounting DIN Rail
Country of Origin Singapore

 

Main Features and Advantages

The ALLEN-BRADLEY 1734-ADN delivers core value by integrating DeviceNet connectivity, POINTBus management, and automated configuration features into a compact adapter that simplifies distributed I/O deployment.

Dual-Network Architecture: The ALLEN-BRADLEY 1734-ADN resides simultaneously on the primary DeviceNet network and the POINTBus backplane, functioning as a slave to the network master while acting as a master scanner for POINT I/O modules . This dual-role capability eliminates the need for separate scanner hardware, consolidating I/O data collection and network communication into a single module.

Auto-Start Configuration: Series B versions of the ALLEN-BRADLEY 1734-ADN support an auto-start mode that automatically sets all backplane modules to Auto Baud, reads module IDs, sets sequential addresses, and generates a scan list with I/O mapping based on byte, word, or double-word boundaries . This feature drastically reduces commissioning time, allowing the I/O system to be operational before other network nodes are added.

Auto Device Replacement (ADR): The ALLEN-BRADLEY 1734-ADN supports ADR functionality, automatically transferring configuration parameters from a failed module to its replacement . When an identical module is inserted, the adapter assigns the original node number and downloads stored configuration data, minimizing downtime and eliminating manual reconfiguration.

Autobaud Detection: The adapter automatically detects the DeviceNet network baud rate and configures itself to match, supporting 125K, 250K, and 500K bits per second . This feature simplifies network integration and prevents communication errors caused by mismatched baud rates.

Removal and Insertion Under Power (RIUP): The ALLEN-BRADLEY 1734-ADN supports RIUP, allowing modules to be replaced while the system remains powered . Combined with the removable wiring system, this capability enables maintenance and expansion without process interruption.