Product Overview
The Siemens 6DD2920-0AL0 is an AUL2 trigger monitoring and evaluation logic module, purpose-built for the power section of SIMADYN D thyristor converter stacks. Its first critical distinction — and the one that trips up engineers new to the platform — is where it lives: the 6DD2920-0AL0 does not plug into the SIMADYN D Euro-rack backplane alongside PM4/PM5/PM6 processors. Instead, it mounts as a daughter/sub-module onto a SAV21 or SAV22 power interface module (Leistungsteil-Interface), which itself sits in the power/trigger chain between the SIMADYN D processor’s IT (impulse/trigger) board and the thyristor valve gates. The AUL2 designation comes from the German AuswertungsLogik (evaluation logic) for trigger monitoring — the module’s job is to watch what the firing pulses are actually doing at the valve level and kill them the moment something drifts.What the Siemens 6DD2920-0AL0 does internally is pure hardware: two independent trigger-monitoring channels, each accepting 200 mA–2 A firing current range, with dV/dt sensing on the thyristor anode–cathode voltage to detect false turn-on, pulse loss, short-circuit, and commutation failure. Response is <10 µs from fault detect to pulse-block — completely bypassing the PM’s software scan cycle. In a rolling-mill main drive or HVDC valve group where a single thyristor misfire cascades into a stack-killer fault, that hardware-level fast trip is the difference between “alarm + clean shutdown” and “blown fuses + week-long rebuild.” The 6DD2920-0AL0 gets its 24 V DC from the SAV21/SAV22 carrier’s isolated internal rail, talks to the carrier via the local pin header (not PROFIBUS, not C-Bus, not L-Bus), and raises a hardware alarm output plus LED per channel when something trips.Critical for spare-pool managers: Siemens canceled the 6DD2920-0AL0 effective April 1, 2008 with the explicit status “abgekündigt ohne Ersatz” — canceled without substitution . There is no AUL3, no TDC-era replacement, no SINAMICS analog that drops onto SAV21/SAV22. If your SIMADYN D power section still runs SAV21/SAV22 (which most 1995–2008 vintage mills/hydro/HVDC do), the Siemens 6DD2920-0AL0 is a dead-end spare — NOS or verified-pull is the only path, and the “no sub” status means you can’t even cross-specify.
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | 6DD2920-0AL0 |
| Manufacturer | Siemens |
| Product Type | AUL2 Trigger Monitoring & Evaluation Logic Module |
| Carrier / Parent Module | SAV21 or SAV22 Power Interface Module (mounts as sub-module) |
| Trigger Channels | 2 independent channels |
| Trigger Current Range | 200 mA – 2 A per channel |
| Supply Voltage | 24 V DC (sourced from SAV21/SAV22 isolated internal rail) |
| Fault Detection | Pulse loss, false turn-on (dV/dt), short-circuit, overcurrent, commutation failure |
| Response Time | < 10 µs (fault detect → pulse block) |
| Monitoring Principle | Hardware dV/dt on thyristor anode–cathode voltage, pure logic (no firmware scan) |
| Fault Indication | Per-channel LEDs + optional hardware alarm output |
| Operating Temperature | -20 °C to +60 °C (follows SAV21/SAV22 carrier rating) |
| Storage Temperature | -40 °C to +70 °C |
| Relative Humidity | 5% – 95% (non-condensing) |
| Dimensions (H × W × D) | 90 × 100 × 60 mm |
| Weight | ~0.3 kg |
| Protection | IP20 (installed inside cabinet / SAV carrier) |
| Certifications | CE, UL, CSA |
| Lifecycle Status | Canceled 2008-04-01, without substitution (PM490) |