Product Overview

The​​ICS Triplex T8111C​​represents the pinnacle of safety system technology,designed as a Triple Modular Redundant(TMR)controller for critical process protection applications.As part of the trusted ICS Triplex safety system family,the​​T8111C​​delivers unparalleled reliability through its advanced three-channel architecture that ensures continuous operation even in the event of single or multiple component failures.This robust safety controller executes complex safety logic with precision,providing fault-tolerant control for the most demanding industrial applications where system failure is not an option.The​​ICS Triplex T8111C​​incorporates advanced diagnostics and voting logic across three independent processing channels,ensuring maximum availability while maintaining the highest safety integrity levels.

Engineered for extreme reliability,the​​ICS Triplex T8111C​​features comprehensive hardware and software redundancy that eliminates single points of failure.Each of the three independent processing channels operates simultaneously,with advanced voting circuits comparing outputs to ensure correct operation.The controller’s robust design withstands harsh industrial environments,maintaining operation across wide temperature ranges and in electrically noisy conditions.The​​ICS Triplex T8111C​​supports extensive diagnostic capabilities that continuously monitor system health,providing early warning of potential issues and facilitating predictive maintenance.With its proven track record in critical industries,this safety controller sets the standard for protection systems in applications where safety and reliability are paramount.

Technical Specifications

Parameter Name

Parameter Value

Product Model

​​T8111C​​

Manufacturer

ICS Triplex

Product Type

Triple Modular Redundant Safety Controller

Architecture

TMR(Triple Modular Redundant)

Safety Level

SIL3

Processor

Triple 32-bit RISC

Memory Capacity

64MB per channel

I/O Capacity

4096 points

Scan Time

10ms

Programming

Relay Ladder Logic,Function Block Diagram

Communication

Triple Ethernet,RS-232,RS-485

Protocol Support

Modbus TCP/IP,OPC

Operating Voltage

24VDC±10%

Power Consumption

15W

Operating Temperature

-40°C to+70°C

Storage Temperature

-40°C to+85°C

Vibration Resistance

5g 50-2000Hz

Certification

SIL3,TÜV,UL,CE

MTBF

>1,000,000 hours

Availability

99.9999%

Main Features and Advantages

The​​ICS Triplex T8111C​​delivers exceptional fault tolerance through its Triple Modular Redundant architecture,featuring three independent processing channels that operate in parallel with continuous output voting.This design ensures that no single point of failure can compromise system operation,providing the highest level of safety integrity with SIL3 certification.The controller’s advanced diagnostics monitor each channel’s performance continuously,detecting and isolating faults while maintaining full system operation.With a proven MTBF exceeding 1,000,000 hours and 99.9999%availability,the​​T8111C​​sets the industry standard for reliability in critical safety applications.

Performance and flexibility:The​​ICS Triplex T8111C​​offers impressive processing power with triple 32-bit RISC processors and 64MB memory per channel,handling complex safety logic and extensive I/O configurations.The controller supports multiple programming languages including relay ladder logic and function block diagrams,providing flexibility for implementing custom safety strategies.Comprehensive communication capabilities including triple Ethernet ports and serial interfaces enable seamless integration with DCS systems,HMIs,and enterprise networks.The robust construction ensures reliable operation in extreme environmental conditions,with wide temperature tolerance and high vibration resistance making it suitable for the most challenging industrial installations.

Application Field

The​​ICS Triplex T8111C​​is deployed in industries where safety and reliability are non-negotiable.In oil and gas applications,it provides critical protection for offshore platforms,pipeline systems,and refinery process units,ensuring safe shutdown and emergency response.The power generation industry relies on the​​T8111C​​for turbine control,boiler protection,and nuclear safety systems where equipment failure could have catastrophic consequences.Chemical and petrochemical plants utilize this controller for reactor protection,flare control,and hazardous area monitoring,preventing dangerous situations through reliable safety interlocks.

Critical infrastructure applications benefit from the​​ICS Triplex T8111C​​’s proven reliability in LNG terminals,gas compression stations,and distribution facilities.The marine industry employs these controllers for engine room safety systems and dynamic positioning control on vessels and offshore installations.In transportation,the​​T8111C​​ensures safety in tunnel control systems,railway signaling,and airport safety operations.Its unmatched reliability makes it the preferred choice for any application where human safety,environmental protection,and asset preservation are paramount concerns.

Related Products

​​ICS Triplex T8461​​-Analog Input Module

​​ICS Triplex T8431​​-Digital Input Module

​​ICS Triplex T8471​​-Analog Output Module

​​ICS Triplex T8441​​-Digital Output Module

​​ICS Triplex Power Supply​​-Redundant power units

​​ICS Triplex Communication Module​​-Network interface units

​​ICS Triplex Baseplate​​-Controller mounting system

​​ICS Triplex Programming Software​​-Safety logic configuration

​​ICS Triplex HMI​​-Operator interface stations

​​ICS Triplex Historian​​-Data recording and analysis

Installation and Maintenance

Pre-installation preparation:Before installing the​​ICS Triplex T8111C​​,verify compatibility with existing safety system architecture and ensure adequate space for proper ventilation and maintenance access.Confirm power supply specifications meet the redundant 24VDC requirements and prepare all necessary mounting hardware and communication cables according to manufacturer specifications.Ensure proper grounding and electrical isolation to prevent interference and ensure safe operation in hazardous areas.

Maintenance recommendations:Implement rigorous preventive maintenance for the​​ICS Triplex T8111C​​,including regular visual inspections for physical integrity,connection security,and environmental conditions.Monitor operating temperatures and ensure adequate ventilation to maintain optimal performance.Regularly perform diagnostic tests and system exercises to verify redundant channel operation and voting logic functionality.Maintain comprehensive documentation of all maintenance activities and system modifications.Utilize the advanced diagnostic capabilities to monitor system health continuously and address potential issues before they impact system availability.

Product Guarantee

We guarantee that every​​ICS Triplex T8111C​​controller is genuine OEM product with full manufacturer warranty and certification intact.Our technical support team provides comprehensive services from safety system design and risk assessment through commissioning and ongoing maintenance support.Choose our solutions for uncompromised safety and reliability in your most critical applications,backed by our commitment to quality and customer safety excellence.