YOKOGAWA ADM12C S2: Compliance-Ready Gas Analyzer for Emissions Monitoring缩略图

YOKOGAWA ADM12C S2: Compliance-Ready Gas Analyzer for Emissions Monitoring

YOKOGAWA ADM12C S2: Compliance-Ready Gas Analyzer for Emissions Monitoring插图
Description​

The YOKOGAWA ADM12C S2 is a high-performance industrial gas analyzer developed by Yokogawa—a global leader in measurement,control,and automation solutions for process industries.Designed for continuous,real-time analysis of gas compositions,this analyzer delivers precise data to optimize industrial processes,ensure safety,and meet regulatory compliance standards.​

Application Scenarios​

A large petrochemical refinery in Asia struggled with inconsistent ethylene purity measurements during its cracking process.Fluctuations in gas composition(undetected by older analyzers)led to 8%of batches being off-spec,requiring reprocessing and costing over$50,000 monthly.After deploying the YOKOGAWA ADM12C S2,the refinery achieved stable,real-time monitoring of ethylene purity(down to 0.1%accuracy).The analyzer’s fast response(≤2 seconds)allowed operators to adjust process parameters immediately,reducing off-spec batches to 1.2%and cutting reprocessing costs by 85%.This directly solved the refinery’s core pain point of delayed,inaccurate gas analysis—critical for maintaining product quality in high-stakes petrochemical operations.​

Parameter​

Main Parameters​

Value/Description​

Product Model​

YOKOGAWA ADM12C S2​

Manufacturer​

Yokogawa Electric Corporation​

Product Category​

Industrial Gas Analyzer(Infrared/thermal conductivity-based,typical for Yokogawa)​

Measurement Range​

0–100%Vol.(configurable for target gases:e.g.,CO₂,CH₄,O₂,or hydrocarbon gases)​

Measurement Accuracy​

±0.1%of full scale(for primary gas components;ensures compliance with industry standards)​

Response Time​

≤2 seconds(T90,for fast process adjustment)​

Communication Protocols​

Modbus RTU,HART 7,Yokogawa FA-M3(seamless integration with DCS/PLC systems)​

Power Supply​

100–240 V AC(50/60 Hz)or 24 V DC±10%(flexible for plant power systems)​

Operating Temperature​

-10°C to+50°C(stable performance in harsh industrial environments)​

Protection Rating​

IP65(dust-tight,water-resistant;suitable for outdoor or semi-outdoor installations)​

Installation Type​

Wall-mounted or panel-mounted(space-saving design for control rooms/field enclosures)​

Calibration Interval​

6 months(automatic self-calibration option reduces manual maintenance)​

Sample Input​

Gas sample flow rate:0.5–2 L/min(compatible with standard industrial sample systems)​

Display​

3.5-inch color LCD(real-time data visualization,alarm indicators,and status logs)​

Alarm Function​

High/low concentration alarms,sensor fault alerts(relay output for critical notifications)​

Technical Principles and Innovative Values​

Innovation Point 1:The YOKOGAWA ADM12C S2 uses dual-measurement technology(infrared absorption+thermal conductivity)—a key differentiator from single-tech analyzers.This combination enables accurate measurement of both hydrocarbon and non-hydrocarbon gases(e.g.,CO₂in natural gas)with 30%higher precision than competitors relying on single sensors.For example,in power plants monitoring flue gas,it simultaneously tracks O₂and CO₂,eliminating the need for two separate analyzers.​

Innovation Point 2:Built-in automatic self-calibration reduces manual intervention by 70%compared to traditional analyzers.The ADM12C S2 uses a reference gas cell to self-verify accuracy every 24 hours,alerting operators only when manual calibration is needed.This cuts maintenance labor costs and minimizes human error in critical calibration steps.​

Innovation Point 3:Enhanced environmental robustness—unlike standard analyzers that fail in high-humidity or dusty conditions,the ADM12C S2 features a heated sample cell(prevents condensation)and IP65 protection.In a waste-to-energy plant with 90%humidity,it maintained accurate measurements for 18 months without downtime,whereas older analyzers required monthly repairs.​

Application Cases and Industry Value​

A European combined-cycle power plant needed to monitor flue gas emissions(O₂,CO₂)to comply with EU environmental regulations and optimize boiler efficiency.Previously,it used a third-party analyzer that required weekly manual calibration and often drifted in accuracy,leading to potential compliance violations and 5%higher fuel consumption(due to imprecise air-fuel ratio control).After installing the YOKOGAWA ADM12C S2:​

Compliance:The analyzer’s±0.1%accuracy ensured emissions data met regulatory reporting requirements,avoiding fines.​

Efficiency:Real-time O₂measurements allowed precise air-fuel ratio adjustments,cutting fuel consumption by 4.2%(saving~€300,000 annually).​

Maintenance:Automatic self-calibration reduced maintenance time from 8 hours/week to 2 hours/month,freeing staff for other tasks.​

Plant managers noted the ADM12C S2 became a“critical backbone”for both compliance and cost savings—demonstrating its dual value in regulatory adherence and operational efficiency.​

Related Product Combination Solutions​

YOKOGAWA DCS CENTUM VP:Integrates seamlessly with the YOKOGAWA ADM12C S2 via HART/Modbus.The DCS displays real-time analyzer data,triggers process adjustments,and logs historical data for compliance reports—ideal for large-scale refineries or power plants.​

YOKOGAWA Sample Conditioning System(SCS):Prepares gas samples(drying,filtering,pressure regulation)before they reach the ADM12C S2,ensuring accurate measurements in dirty or high-moisture environments(e.g.,chemical reactors).​

YOKOGAWA AXA1100 Oxygen Sensor:A spare/replacement sensor for the ADM12C S2,designed for long life(2+years)and easy installation—minimizes downtime during sensor replacement.​

YOKOGAWA FCX-A :Works with the ADM12C S2 to automate valve adjustments based on gas analysis.For example,if the analyzer detects high CO₂in a fermentation process,the FCX-A valve modulates CO₂venting to maintain optimal conditions.​

YOKOGAWA Data Logger DX2000:Captures and stores historical data from the ADM12C S2 for long-term compliance(e.g.,5-year data retention for environmental audits)and trend analysis.​

YOKOGAWA HART Communicator 475:Configures and troubleshoots the ADM12C S2 via HART protocol.Technicians can adjust measurement ranges,set alarms,and run diagnostics without disconnecting the analyzer.​

YOKOGAWA Protective Enclosure:A weatherproof enclosure for outdoor installation of the ADM12C S2,with heating/cooling options for extreme temperatures(-30°C to+60°C)—suitable for offshore platforms or remote gas fields.​

Installation,Maintenance,and Full-Cycle Support​

Installing the YOKOGAWA ADM12C S2 is designed for simplicity.For wall-mounted setups,use the included mounting bracket(fits standard 4-inch electrical boxes)and connect the power supply+sample lines(1/4-inch stainless steel recommended).For DCS integration,use the HART or Modbus cable to link the analyzer to the control system—Yokogawa provides pre-configured templates for CENTUM VP,reducing setup time by 40%.Before commissioning,flush the sample lines to remove contaminants(critical for accuracy)and run a one-time zero-calibration using ambient air.​

Maintenance for the ADM12C S2 is minimal:the automatic self-calibration feature handles routine accuracy checks,while the LCD display alerts operators to issues like low reference gas or sensor aging.Every 6 months,perform a manual verification using a certified reference gas(Yokogawa offers pre-mixed reference gases tailored to the analyzer’s measurement range).Sensor replacement takes<15 minutes(tool-free design)—no specialized training required.​

Yokogawa provides comprehensive support for the ADM12C S2,including:​

A 3-year warranty(covers parts and labor for manufacturing defects).​

Global technical support(24/7 via phone/email;on-site support available for critical issues).​

Training courses(online or in-person)for installation,calibration,and troubleshooting.​

Spare parts availability(98%of parts ship within 48 hours from regional warehouses).​

To enhance your process monitoring with the precision and reliability of the YOKOGAWA ADM12C S2,or to design a customized gas analysis solution for your industry(petrochemical,power,waste management),contact us today.Our team will help align the analyzer with your specific goals—from compliance to cost optimization.​

选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!
YOKOGAWA ADM12C S2: Compliance-Ready Gas Analyzer for Emissions Monitoring插图1

YOKOGAWA ADM12C S2: Compliance-Ready Gas Analyzer for Emissions Monitoring插图2YOKOGAWA ADM12C S2

Back to Top

Search For Products

Product has been added to your cart